STAR Line Mode Command Specifications

1-3


3) General description of operations in the XON/XOFF mode
This mode is set when DIPSW #1 to #3 are turned OFF. This mode notifies the host of the XON (DC1) data when the
printer can receive data and the XOFF (DC3) data when the printer cannot receive data, using the TXD signals.
This functions so that XON outputs only 1 byte when the printer shifts from OFFLINE (printer busy) to ONLINE (printer
ready) and; XOFF outputs 1 byte when the printer shifts from ONLINE (printer ready) to OFFLINE (printer busy) .
















If there is no error after turning the power ON, XON (control code name: DC1; Hexadecimal name: 11H) is output by the
TXD signal line. After the host computer receives the XON, it sends the data text to the RXD signal line. XOFF (DC 3;
13H) is output when the empty space in the data buffer is a maximum of 256 bytes. The host computer stops sending
data text when it receives the XOFF, however, the printer is capable of receiving data at that time for the amount of
empty space in the data buffer. Data exceeding the amount of empty space is discarded. As the empty space in the
data buffer increases through printing, XON is output when the data in the buffer is a maximum of 256 bytes.



4) Buffer full/Buffer full cancel in the XON/XOFF mode

Full

Near Full Near Empty

Empty

Buffer Empty area: 256 bytes

Reception data: 256 bytes

XOFF Output

XON Output




Printer Setting Conditions

Explanation of Operations

Memory switch B-4 = 0

XOFF outputs only 1 byte when the empty area is a maximum of 256
bytes. XON outputs 1 byte when the data in the buffer is a maximum
of 256 bytes.

Memory switch B-4 = 1

XOFF output for every 1 byte of data received, when the empty area
is a maximum of 256 bytes. XON output when the data in the buffer is
a maximum of 256 bytes.


XON XOFF XON XOFF XON

TXD

RXD DATA DATA DATA

Printing

Out of

paper

signal

Power ON No paper ON-LINE Recovery