beautypg.com

Code 93, Nw7 (coderbar) – Star Micronics Line Thermal Printer User Manual

Page 146

background image

―――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――

STAR Line Mode Command Specifications

5-5

5.1.5. Code

93


1. Each mode and module width

Items

Mode 1

Mode 2

Mode 3

Module Width

2 dots

3 dots

4 dots

Length of 1 Character (*)

2.25 mm

3.375 mm

4.5 mm

(*) Start and stop bars not included.


2. Regulations

• Start/stop codes are automatically applied.

• Check character (C, K) is automatically applied.

• 2 character set expression conforms to Code 128.

However, items marked with a star are codes that can only be used with Code 128, and not with Code 93.




5.1.6. NW7

(CODERBAR)

NW7 normally uses either A through D as the start/stop codes and represents special symbols (- (minus sign)/$ (dollar
sign)/: (colon)// (slash)/. (period)/+ (plus sign) between 0 to 9.
These are used as carrier package marking bar codes, DPE (photo prints) and for medical related industries (USA).

1. Length of 1 character in each mode

Items

Mode 1

Mode 2

Mode 3

Mode 4

Mode 5

Mode 6

Mode 7

Mode 8

Mode 9

Narrow

Element

Width

2 3 4 2 3 4 2 3 4

Wide

Element

Width 6 9 12 5 8 10 4 6 8

Ratio 1:3

1:3

1:3

1:2.5

1:2.7 1:2.5 1:2 1:2 1:2

Character Spacing

(Dots)

2 3 4 2 3 4 2 3 4

Length of 1 Character

(Normally mm)

(Width mm)

3

3.5

4.5

5.25

6
7

2.75

3.125

4.25

5.125

5.5

6.25

2.5

2.75

3.75

4.125

5

5.5


• With NW7, lengths differ because narrow elements and wide elements are included according to the characters.
• Normal characters (narrow: 5, wide: 2) and numbers (0 to 9), - and $
• Wide characters (narrow: 4, wide: 3) ,/,.,+, A to D
• Character spaces are included in 1 character length.