Robot Installation

30

Adept Viper s1700D Robot User’s Guide, Rev A

Figure 2-7. Ceiling Mounting

2.6

Grounding the Robot

NOTE: Use a dedicated grounding wire and grounding electrode. Do not
share them with any other electric power or power equipment, such as a
welder. When metal ducts, metallic conduits, or distributing racks are
used for laying cable, ground in accordance with Electric Equipment
Technical Standards.

DANGER:

Ground the grounding terminal of the robot

unit with a wire of 5.5 mm

2

or more. Ground resistance

must be less than 100 milliohms.

WARNING:

Wiring must be performed by authorized or

certified personnel. Failure to observe this caution may
result in fire or electric shock.

(Tensile strength: 1200 N/mm

2

)

Hexagon socket head cap screws M16 (4 screws)

Robot base

Preventive support from falling