The oil dipper must be properly

installed on the number 1 connect­

ing rod, as shown at right. A

special washer is installed be­

tween dipper and bolt head.

OIL M A K E - U P SYSTEM

The Oil Make-up System functions to prevent dangerously low engine

crankcase oil levels during operation. The system consists of (1) an

Oil Make-up TANK with low oil level shutdown switch, (2) an Oil Make­

up PUMP, (3) an Oil Make-up PROBE, and (4) interconnecting lines.

t

The Oil Make-up' Pump will not act

while the tip of the Oil Make-up

Probe is submerged in oil. If oil

level in the crankcase should drop

to about the 48 ounce level, the

tip of the Probe will be exposed to

crankcase vacuum/pressure pulses.

These pulses actuate the Oil Make­

up Pump diaphragm and the pump ac­

tion then draws oil from the Tank. ■

When the Probe tip is again submerg­

ed in oil, pumping action stops.

If Oil Make-up Tank oil level

should drop below the OIL CHANGE

LEVEL arrows on the tank side,

the float-operated Low Oil Level

Shutdown Switch will ground the

engine ignition system and the

engine will automatically shut

down.

During initial filling of the engihe

crankcase, approximately 56 ounces

(3^ pints) of oil is added. This a-

mount of oil brings the oil level up

to the oil dipstick FULL mark. The

Oil Make-up System will not start to

pump oil into the crankcase until

oil level has reached the 48 ounce

point, about halfway between the dip­

stick FULL mark and ADD 1 PINT mark.

Issued 4-78