TEST 9

- O I L MAKE-UP TANK

A.) Check Oil level in Oil Make-up

Tank. If oil level is near OIL

CHANGE LEVEL arrows, refill tank

with same, type and grade of oil

used in engine crankcase.

RESULTS: 1.) Oil level LOW..

2.) Oil level.GOOD.

.Refill tank

.Continue

tests

in

"Diagnostic

Flow Charts", Section 3

TEST

10

-

LOW OIL SWITCH

A.) Remove one screw that retains the Low Oil Switch Cover. Move Cover

out of the way.
Set VOM to "+DC" and to "Rxl" scale. Connect meter test probes and zero

the meter. Connect one meter test probe to lower left switch terminal

and remaining probe to ground terminal (bottom of switch). With switch

actuating lever DOWN (low oil condition), meter needle should swing up­

scale to "Zero". If meter

A.) Remove one screw that retains the Low Oil Switch Cover. Move Cover

out of the way to.expose switch terminals.

Set VOM to "+DC" and to "Rxl"

scale. Connect meter test probes

and "zero" thé meter. Connect

one test probe to lower left

switch terminal. Connect remain­

ing test probe to ground. With

switch actuating lever DOWN (low

oil level), meter needle should

swing upscale to "zero". With

switch actuating lever UP (norm­

al oil level), meter needle should

drop all the way downscale to

"infinity". MAKE SURE GROUND WIRE

BETWEEN SWITCH BOTTOM TERMINAL AND OIL FILLER. NECK BRACKET SCREW IS

TIGHT.