RESULTS: 1.) Checks BAD................................................Replace Ignition Coil

2.) Checks Good...........................................Continue with Paragraph "B"

B.) Set VOM to "RxlOO" scale and zero

the meter. Unplug both spark plug

wires from Ignition Coil, and in­

sert the two meter test probes as

shown. Meter needle should indicate

secondary winding resistance, about

6500 ohms.

RESULTS: 1.) Checks Bad.............Replace. Ignition Coil

2.) Checks Good...................................Continue with Paragraph "C"

C.) Set VOM to ”Rxl0,000" scale and zero the meter. Connect one

meter test probe to Ignition Coil as in Paragraph ”B”, but conn­

ect the second probe to ground. Meter needle shonld not swing

upscale (infinity).

RESULTS: 1.) Meter swings upscale.... Replace Ignition Coil

2.) Meter does not move........................... Continue with tests in

"Diagnostic Flow Charts",

Section 3

TEST 15

-LOW FUEL LEVEL

A.) Check fuel level in gas. tank.

The vehicle engine fuel pickup

tube in the tank, is usually sev­

eral inches longer than the alter­

nator pickup tube. This means that,

even if adequate fuel is available

for vehicle engine operation, the

fuel may be below the alternator fuel

pickup tube.

To Alternator

Engine

To Vehicle

Engine

To Alternator

Engine

Fuel

Tank

ik

p

\1

Pipe Cap

_L

Pipe
Nipple

Variable
Potentiometer ^

3 In

\ Anti-Siphon
■^Holes

1'

3 in.

To Vehicle
Engine

Fuel Gauge

Connection

Fuel

Quantity

Float

Installation Of Second

Fuel Pick Up Tube In

Tank Outlet.