Ad just Jets: Turn Needle Valve

clockwise until it just closes -

DO NOT TURN IN TOO FAR, OR JET

MAY BE DAMAGED. Then open needle

valve

l\

turns (counterclockwise).

Close Idle Valve in same manner,

then open 1^ turns. This initial

adjustment will permit the engine

to be started and warmed up.

TEST 23 -

CARBURETOR

With engine running, hold the throttle lever against the Idle Stop. Set

the Idle Speed Adjusting Screw to obtain 1400 rpm. Turn Idle Valve SLOW­

LY clockwise to obtain 1400 rpm, 93 volts AC, or 46 Hz. Then turn Idle

Valve SLOWLY clockwise (lean mixture) until engine misses or engine

speed slows. Finally, turn Idle Valve one-half turn counterclockwise.

Hold throttle lever against idle

stop and turn Idle Speed Adjust­

ing Screw to obtain 900 rpm (30

Hertz or 60 Volts a-c). Then bend

Governed Idle Tab (see illustrat­

ion at right) to obtain 1400 rpm

(93 Volts a-c or 46 Hertz).___________________

NOTE

Governed idle must be adjusted

for proper operation. The smaller

spring keeps the engine on govern

nor, even at idle speed. Idle

speed should not be lower then

1100 rpm, 73 volts or 37 Hz.

Release throttle lever and let'engine accelerate to governed speed.

Apply a load to the alternator, between'3000 and 4500 watts. Turn

Needle valve SLOWLY clockwise (lean mixture) until voltage reading

starts to drop off. Then turn Needle Valve counterclockwise until

the highest voltage reading is obtained. When the highest voltage

is obtained, turn the Needle Valve counterclockwise an additional

1/8

of a turn.

Check Float Valve and Seat; Refer to engine section of this Manual

for procedures. Inspect float valve and its seat for damage, dirt

or wear.

Check Float Level; Refer to engine section of this Manual for pro­

cedures .

4.14