2. Mount Rotor.to Fan bosses. Use two
flat washers under each ,5/16-18 x 3/4
inch long capscrew - RAD.IUS. 0R_ CHAMF
ERED SIDE OF WASHER,
must
: BE AGAINST
FLEK. C.OUELIN.G., Apply LOG-TITE 601 to
capscrew threads. Install capscrews
and torque to 19 Foot-Pounds.
STATOR
1. If previously removed, align
alternator adapter with stator can
and install. Slide alternator ada
pter and stator can carefully over
the rotor, with stator bolt holes
in engine adapter and alternator
adapter aligned. Seat the mating
flanges of engine and alternator
adapter against each other.
REAR BEARING CARRIER
2. Slide a rubber vibration damp
ener into place over slide pan
hole. Install bolt, with bolt head
at bottom of slide pan. Install
metal spacer, rubber washer, metal
washer, lockwasher and hex nut. Re
peat for second vibration dampener.
Tighten both hex nuts.
1. Pull wire bundles through snap bushing in Rear Bearing Carrier. Then
align Carrier with rotor bearing and with threaded holes in engine ada
pter. Lightly tap Carrier over rotor bearing.. Install four stator bolts»
with lockwashers. Grounding lug goes under upper left hand bolt, fuel
pump ground wire under lower left bolt. Retain fuel shutoff solenoid
clamp next to brush inspection window.