2, Make sure all four stator bolts
are tightened down evenly. Engine
adapter to alternator adapter mat
ing flanges must be flush, as well
as stator can to Rear Bearing Car
rier mating flanges.
CONTROL PANEL
Refer to CONTROL PANEL:REMOVAL on
Pages 5.4 through 5.6. Retain the
Control Panel to stator can using
four capscrews and lockwashers.
Connect all wiring previously dis
connected. Refer to a wiring diag
ram for the specific unit for cor
rect wiring connections. Use tie
wrap for neater wire bundles and
for wiring support where necessary.
When installing brushes and brush
holder, the red (No.. 4) wire goes
next to the rotor bearing. Brush
ground wire extends from the other
brush - retain the ground wire .
with one of the brush holder reta
ining screws.
Issued 3-78