2, Make sure all four stator bolts

are tightened down evenly. Engine

adapter to alternator adapter mat­

ing flanges must be flush, as well

as stator can to Rear Bearing Car­

rier mating flanges.

CONTROL PANEL

Refer to CONTROL PANEL:REMOVAL on

Pages 5.4 through 5.6. Retain the

Control Panel to stator can using

four capscrews and lockwashers.

Connect all wiring previously dis­

connected. Refer to a wiring diag­

ram for the specific unit for cor­

rect wiring connections. Use tie

wrap for neater wire bundles and

for wiring support where necessary.

When installing brushes and brush

holder, the red (No.. 4) wire goes

next to the rotor bearing. Brush

ground wire extends from the other

brush - retain the ground wire .

with one of the brush holder reta­

ining screws.