ALTERNATOR

6

r e a r

b e a r i n g

c a r r i e r

REMOVAL

1. Remove Control Panel as outlined in Section 5.

■Xtic.-;

i!.

- ■

1

2. Remove the Fuel Shutoff Solenoid

Clamp screw. Tape o.r cover the open

end of the Fuel Filter to prevent

entry of dirt. Lay the Filter, Sol­

enoid and hoses out of the way.

4. Use a 7/16 inch socket to remove

the 4 stator bolts. Use a wood or

fiber mallet to tap each projecting

corner of the Rear Bearing Carrier.

When Rear Bearing Carrier Is free

of the Rotor bearing, slide the wire

bundle through the snap bushing and

remove the Rear Bearing Carrier.

3. Use a

k

inch nut driver to remove

the 3 screws that retain the Fan

Guard. Remove the Fan Guard.

INSPECTION

1. Check closely for cracks, or other damage.

2. Check condition of snap bushing. Replace, if damaged.

3. Inspect threaded holes for condition of threads, damage, etc. Repair

or retap, as required.