DIODES D1 & D2

Diodes Dl and D2 are a part of the

battery charging circuit. They fun­

ction to convert the a-c output of

the battery Charge windings, to dir­

ect current (d-c). Battery.charge ,

circuit checks are outlined in Tests

42 through 45, Pages 4.24 through

4,26, When replacing a defective di­

ode, bleed off excessive .heat by

means of a heat sink - dfodes are ex­

tremely sensitive to. heat.

OTHER COMPONENTS

other Control Panel components are

shown at right. These include (1)

a 40 Amp Main Circuit Breaker, (2)

a 15 Amp Fuse, (3) a Start/Stop

Switch, (4) battery Charge Circuit

Breaker, (5) Sensing Transformer,

and (6) Terminal Strip, Refer to

Sections 2 and 3 for troubleshoot­

ing and testing of these, components,

Refer to the Wiring Diagram for

*

each

speci.fic

alternator

model

when

reconnecting components.

PANEL REMOVAL

1, At front of alternator, locate

the large wire bundle from control

panel. Disconnect all wires from

this wire bundle, as follows:

(a) Wire #14 at fuel pump

(b) Wire #20 to Low Oil Switch

(c)

Two Wires #15 at Starter Sol­

enoid

(d) Wire #13 at Starter Solenoid

(e) Wire #17 at Starter Solenoid

(f) Wire #91 at Starter Solenoid

5,4