beautypg.com

Generac Power Systems TXP User Manual

Page 52

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

2,

At

rear of Panel, (a.) disconn­

ect spark plug wires from Ignition

Coil, (b) disconnect the wire con­

nectors A and B,. and (c.) cut the

tie wrap that holds Wires #2 and

#6 to the stator bolt.

3, Remove the Panel top cover.

4. Remove wire nuts and disconnect

wires #11 and #22 to Sensing Tran­

sformer, as well as Wire #55 to

Diode Dl. Disconnect wire #66 at

terminal strip. Disconnect wire #

77 at battery charge circuit brea­

ker. Disconnect wires #11 and #33

from main circuit breaker and pull

through the snap bushing.' Remove

wire nuts from two. wires #T2 and

pull through snap bushing. Pull all

wires through snap bushing at

rear floor of panel.

5. At the rear exterior floor of

the control.panel, locate wires #

1, #2, #4 and #6 that connect into

the white receptacle. Use a small

screwdriver or pen knife to "un­

lock” each female pin from its. re­

ceptacle slot, while carefully pul­

ling down on each wire. Remove all

four wires from the white receptac­

le.

Issued 3-78

5.5