A.) Depress locking tangs of Print­

ed Circuit Board connector plug and

disconnect plug from its receptacle.

On the connector plug, locate Pin #

4 to which Wire #20 attaches. Set

the VOM switches to ’.’AC" and to 2,5

Volts, Connect one VOM test probe to

Connector plug Pin #4 and the other

test probe to ground. Crank the eng­

ine - Tneter needle should swing up­

scale

and

indicate

approximately

0,5

volts AC (pulsing voltage),

RESULTS: 1,) Meter indicates 0,5 Volts

2,) Meter does not indicate,,

0,5 volts

TEST 18

- PRINTED CIRCUIT BOARD

,Go to Paragraph ”B”

.Check Wire #20 between Print­

ed Circuit Board and Terminal

Strip, and between Terminal

Strip and Ignition Module for

open or shorted condition.

B.) Plug printed circuit board

connector plug in. Locate Wire

#14 connection at terminal strip.

Set VOM to "+DC" and to ''50V'

scale. Connect POSITIVE (+) meter

test probe to terminal strip wire

#14 connection and other test

probe to ground. Crank the engine.

Meter should indicate battery vol­

tage (9-12 volts DC),

RESULTS: 1,) Meter indicated 12 volts,

2,) Meter did NOT indicate,,.

12

volts

TEST 19 -

FUEL FILTER

Remove and replace the In-Line

Fuel Filter, Make sure arrow on

Fuel

Filter

points

towards

the

solenoid-operated

Fuel

Shutoff

Valve, Repeat TEST 16 on Page

4.10 (No Fuel Flow).

Issued 3-78

• Continue tests in ’’Diagnostic

Flow Charts”, Section 3

Check Wire. #14 between Terminal

Strip and Printed Circuit Board

for open or shorted condition.

If not open or shorted, replace

Printed Circuit Board,