Issued 3-78 – Generac Power Systems TXP User Manual
Page 28
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
CAUTION
Before installing Low Oil Switch Cover, make sure the float arm is
riding on top of the switch actuating lever. If float arm has dropped
off of switch actuating lever, engine will not shut down when oil
level in tank is low.
RESULTS:.!.) Switch tests Bad............................................................ Replace Switch
2.) Switch tests.Good...............Continue tests in "Diag
nostic Flow Charts", Sec
tion 3
TEST
11
-SPARK PLUG
A,) Remove one spark plug. Connect
spark plug wire to plug. Ground
spark plug against engine. Hold
Start/Stop Switch at START and ob
serve spark plug. A sharp, snappy
spark should be seen. Repeat test
for second spark plug.
CAUTION
NEVER crank engine with a spark
plug or spark plug wire removed,
unless the spark plug or wire is
connected to a clean ground.
Failure to ground the plug or
lead can damage the Ignition coil,
RESULTS: 1.) Sharp, snappy spark is
NOT observed.............. ........................ ................ .Replace spark plug
2.) Sharp, snappy spark IS
observed,....... ................................................................ .. .Continue tests in
"Diagnostic* Flow
Charts", Section 3
Test
12
-
IGNITION MODULE
“
A.) Unplug the Ignition Module
from its receptacle. Inspect the
connector pins in the module and
module receptacle - make sure
the pins are not bent or pushed
in. Install a new (or "shop") ig
nition module and check for norm
al spark.
RESULTS: 1.) Normal "hot" sparking...................................................Install a new Ignition
Module, continue tests
2.) Normal sparking NOT observed.... Continue tests in"Diagnos-
tic Flow Charts", Section 3
Issued 3-78