beautypg.com

Hitachi J300U Series User Manual

Page 98

background image

12-7

Display

(Function mode 1)

(Function mode 2)

Setting, change

sequence

Function

Function

Initialization display

Initialization

contents

Setting contents

No.

name

contents

9

F-08

Accelera-

Fsp F

0000.0 Hz

0 Hz

0 to 400.0

• The frequency at which the

Accelera-

tion stop

acceleration operation is

tion halt

frequency

stopped temporarily is set.

setting
Accelera-

Fsp TIME

00.0 s

0 s

0 to 60.0

• The time that the acceleration

tion stop

is stopped temporarily at a

time setting

certain frequency during

acceleration is set.

10

F-09

Pattern

PARAM

REM

REM

REM/

• The parameter setting com-

command-

OP1/OP2

manding source is selected.

ing method

(Option

REM (each operator),

selection

connected)

OP1 (option 1), OP2 (option
2)

11

F-10

Running

mode

Running

RUN MODE

NOR

NOR

NOR/OEN/

NOR:

Normal running

mode

GOD

OEN:

Energy conservation

selection

running

GOD:

Fuzzy most suitable
acceleration and
deceleration running

Restarting

RUN FRS

ZST

ZST

fST/ZST

fST:

Restart after frequency

after FRS

maching

signal

ZST:

0 Hz start

selection

12

F-11

Multistage

SPD 1

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminal CF1 is set

Multistage speed

and used.

speed

1 speed
setting
Multistage

SPD 2

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminal CF2 is set

speed

and used.

2-speed
setting
Multistage

SPD 3

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminals CF1 and

speed

CF2 are set and used.

3-speed
setting
Multistage

SPD 4

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminals CF1 and

speed

CF3 are set and used.

4-speed
setting
Multistage

SPD 5

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminals CF2 and

speed

CF3 are set and used.

5-speed
setting
Multistage

SPD 6

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminals CF1, CF2,

speed

and CF3 are set and used.

6-speed
setting
Multistage

SPD 7

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminal CF3 is set

speed

and used.

7-speed
setting