12-6

Display

(Function mode 1)

(Function mode 2)

Setting, change

sequence

Function

Function

Initialization display

Initialization

contents

Setting contents

No.

name

contents

6

F-05

Motor

AUX M

123.60 mH

Rated capacity

0 to 655.35

• Primary self inductance per

Motor

M setting

of each inverter

phase.

constant

constant
Motor

AUX J

0.44 kgm

2

Rated capacity

0 to 655.35

• Motor and machine inertia

J setting

of each inverter

constant
Motor

AUX Kp

002.00

2.0

0 to 100.00

• Smaller: High response

constant

• Larger: Low response

Kp setting
Motor

AUX Ti

00100 ms

100 ms

0 to 10000

• Set this item after the

constant

feedback option PCB is

Ti setting

installed.

Motor

AUX KPP

001.00

1.0

0 to 100.00

• Set this item after the

constant

feedback option PCB is

KPP setting

installed.

7

F-06

Accelera-

ACC 1

0030.00 s

30.00 s

0.01 to 3000

• When the fuzzy most

Accelera-

tion time

suitable acceleration and

tion time

setting

deceleration (F-10) are set,

the time displayed here is
invalid, though it can be
set.

2-stage

ACC 2

0015.00 s

15.00 s

0.01 to 3000

• The acceleration time can

acceleration

be used when the input

time setting

terminal CH1 is shorted.

• For input terminal

selection, refer to F-34
input terminal.

Curve

ACC LINE

L

L

L (Linear),

• The curve pattern is set for

pattern

S (S curve),

acceleration and

selection

U (U curve),

deceleration respectively.

for

RU (reverse

acceleration

U curve)

Accelera-

ACC GAIN

02

2 (common to

1 to 10

• When the constant is set

tion and

acceleration

for one of acceleration and

deceleration

and

deceleration, it is common

curve

deceleration)

to both acceleration and

constant

deceleration.

selection

• See appendix 4.

8

F-07

Decelera-

DEC 1

0030.00 s

30.00 s

0.01 to 3000S

• When the fuzzy most

Decelera-

tion time

suitable acceleration and

tion time

setting

deceleration (F-10) are set,

the time displayed here is
invalid, though it can be
set.

2-stage

DEC 2

0015.00 s

15.00 s

0.01 to 3000S

• The deceleration time can

deceleration

be used when the input

time setting

terminal CH1 is shorted.

• For input terminal

selection, refer to F-34
input terminal.

Curve

DEC LINE

L

L

L (Linear),

• The curve pattern is set for

pattern

S (S curve),

acceleration and decelera-

selection

U (U curve),

tion respectively.

for

RU (reverse

deceleration

U curve)

Accelera-

DEC GAIN

02

2 (common to

1 to 10

• When the constant is set

tion and

acceleration

for one of acceleration and

deceleration

and decelera-

deceleration, it is common

curve

tion)

to both acceleration and

constant

deceleration.

selection

• See appendix 4.