5-8

Power supply

Magnetic
contactor

ELB

Standard equipment

Motor
output
(kW)

Inverter
model

Wiring

Applicable equipment

Power
lines

R,S,T,U,V
W,P,N

Power
lines
External
resistor

RB1,2,3,
P,RB

Earth leakage
breaker (ELB)

Electro-
magnetic
contactor

5.5

7.5

11

15

22

30

37

45

55

75

90

110

J300-055HF

J300-075HF

J300-110HF

J300-150HF

J300-220HF

J300-300HF

J300-370HF

J300-450HF

J300-550HF

J300-750HF

J300-900HF

J300-1100HF

EX50C(30A)

EX50C(30A)

EX50C(50A)

EX60B(60A)

RX100(75A)

RX100(100A)

RX100(100A)

RX225(150A)

RX225(175A)

RX225(225A)

RX225(250A)

RX400(350A)

H20

H20

H25

H35

H50

H65

H80

H100

H125

H150

H220

H250

AWG 18

Shielded
wire

Signal
lines

Signal
lines

FM,CM1,PCL P24,AL0,AL1
FW,8,7,6,5,4,3 AL2
2,1,H,O,OL,L,
CM2,12,11

When the
number of
shielded
wires to be
used is 11
or more,
the section
of each
shielded
wire
should be
AWG 20.

AWG 16

or more

(400V class)

10
or more

10
or more

AWG 8

or more

AWG 8

or more
AWG 6

or more
AWG 4

or more
AWG 4

or more

AWG 2

or more

AWG 1

or more

AWG 3/0

or more

300
or more

300
or more

350
or more

350
or more

Power
lines

R,S,T,U,V
W,P,N

Motor
output
(kW)

7.5

11

15

22

30

37

45

55

75

90

110

132

AWG 8

or more

AWG 8

or more
AWG 8

or more

AWG 8

or more
AWG 6

or more

AWG 4

or more
AWG 4

or more
AWG 2

or more
AWG 1

or more

AWG 3/0

or more

300
or more

300
or more

Constant torqe

Variable torqe

Motor
output
(kW)

Inverter
model

Wiring (AWG or Kcmil)

Applicable equipment

Power
lines

R,S,T,U,V
W,P,N

Power
lines
External
resistor

RB1,2,3,
P,RB

Earth leakage
breaker (ELB)

Electro-
magnetic
contactor

5.5

7.5

11

15

22

30

37

45

55

J300-055LF

J300-075LF

J300-110LF

J300-150LF

J300-220LF

J300-300LF

J300-370LF

J300-450LF

J300-550LF

EX50C(30A)

EX50C(30A)

EX50C(50A)

EX60B(60A)

RX100(75A)

RX100(100A)

RX100(100A)

RX225(150A)

RX225(175A)

H20

H20

H25

H35

H50

H65

H80

H100

H125

AWG 18

Shielded
wire

Signal
lines

Signal
lines

FM,CM1,PCL P24,AL0,AL1
FW,8,7,6,5,4,3 AL2
2,1,H,O,OL,L,
CM2,12,11

When the
number of
shielded
wires to be
used is 11
or more,
the section
of each
shielded
wire
should be
AWG 20

AWG 16

or more

(200V class)

10

or more

10
or more

AWG 6

or more

AWG 4

or more

AWG 3

or more

AWG 1/0

or more
AWG 3/0

or more
AWG 4/0

or more

300
or more

350
or more

Power
lines

R,S,T,U,V
W,P,N

Motor
output
(kW)

7.5

11

15

22

30

37

45

55

75

AWG 8
or more

AWG 8

or more

AWG 6

or more

AWG 4
or more

AWG 3

or more

AWG 1/0

or more
AWG 3/0

or more
AWG 4/0

or more

300
or more

350
or more

Constant torqe

Variable torqe

J300-1320HF

132

AWG 4 / 0

parallel

160

AWG 4 / 0

parallel

RX400(400A)

H400

J300-1600HF

160

300

parallel

220

300

parallel

RX600(600A)

H600

J300-2200HF

220

350

parallel

260

350

parallel

RX600(600A)

H600

5.4