beautypg.com

A-30 – Hitachi J300U Series User Manual

Page 142

background image

A-30

Display with HOP, HRW Display with DOP, DRW

Function No. with digital operator

Data read/copy

Function mode

Layer

Data display

No.

Data display

Alterability

No.

Data

HRW DRW

Input terminal 1 setting

3-6-3

1 I-1

18:RS

F-34

IN-TM 1 RS

Y

C 0

18

Y

N

Input terminal 2 setting

2 I-2

16:AT

IN-TM 2 AT

Y

C 1

16

Y

N

Input terminal 3 setting

3 I-3

5:JG

IN-TM 3 JG

Y

C 2

5

Y

N

Input terminal 4 setting

4 I-4

11:FRS

IN-TM 4 FRS

Y

C 3

11

Y

N

Input terminal 5 setting

5 I-5

9:CH1

IN-TM 5 CH1

Y

C 4

9

Y

N

Input terminal 6 setting

6 I-6

2:CF2

IN-TM 6 CF2

Y

C 5

2

Y

N

Input terminal 7 setting

7 I-7

1:CF1

IN-TM 7 CF1

Y

C 6

1

Y

N

Input terminal 8 setting

8 I-8

0:REV

IN-TM 8 REV

Y

C 7

0

Y

N

Input terminal 1 NO/NC setting

9 I-OC1

0: NO

IN-TM 0/C-1 NO

Y

C20

00

Y

N

Input terminal 2 NO/NC setting

a I-OC2

0: NO

IN-TM 0/C-2 NO

Y

N

Input terminal 3 NO/NC setting

b I-OC3

0: NO

IN-TM 0/C-3 NO

Y

N

Input terminal 4 NO/NC setting

c I-OC4

0: NO

IN-TM 0/C-4 NO

Y

N

Output terminal 11 setting

d 0-1

0: FA1

OUT-TM 1 FA1

Y

C10

0

Y

N

Output terminal 12 setting

e 0-2

1: RUN

OUT-TM 2 RUN

Y

C11

1

Y

N

Alarm output NO/NC setting

f 0-OCA

1: NC

OUT-TM 0/C-A NC

Y

C21

04

Y

N

Output terminal 11 NO/NC setting

g 0-OC1

0: NO

OUT-TM 0/C-1 NO

Y

N

Output terminal 12 NO/NC setting

h 0-OC2

0: NO

OUT-TM 0/C-2 NO

Y

N

Monitor signal selection

3-6-4

1 SEL

0: A-F

F-37

MONITOR A-F

Y

A44

0

Y

Y

Host operation at OP1 error

4-1

1 OP1

1: STP

F-47

OP-ERR1 STP

N

Y

N

Host operation at OP2 error

2 OP2

1: STP

OP-ERR2 STP

N

Y

N

Encode pulse number setting

4-2

1 ENC-P

1024 pls

F-39

OP P 01024 pulse

N

Y

N

Control mode selection

2 MODE

0: ASR

OP MODE ASR

N

Y

N

Ro-to option selection

3 RO-TO 0: OFF

OP-RO-TO OFF

Y

A99

0

Y

Y

Stop position setting switch

4-3

1 POS

0: IN

F-40

OR POS IN

N

Y

Y

Stop position setting

2 P

0 pls

OR P 00000 pulse

N

Y

N

Speed setting

3 FC

5.0 Hz

OR FC 0005.0 Hz

N

Y

N

Direction setting

4 TURN 0: FWD

OR TURN FWD

N

Y

Y

Completion range setting

5 LIMIT

5 pls

OR L 0005 pulse

N

Y

N

Completion delay time setting

6 TW

0.0 ms

OR TW 00.0 ms

N

Y

N

Electronic gear setting position selection

4-4

1 EGRP

0: FB

F-41

PO EGRP FB

N

Y

Y

Numerator of electronic gear ratio

2 EGR-N 1

PO EGR-N 00001

N

Y

N

Denominator of electronic gear ratio

3 EGR-D 1

PO EGR-D 00001

N

Y

N

Feed forward gain

4 FFWG 0.00

PO FFWG 000.00

N

Y

N

Position loop gain

5 G

0.50 rad

PO G 000.50 rad/s

N

Y

N

Torque limiter setting selection

4-5

1 LIMIT

0: IN

F-42

TRQ LIMIT IN

N

Y

N

Plus torque limiter setting

2 FWD

150 %

TRQ FWD 150 %

N

Y

N

Minus torque limiter setting

3 REV

150 %

TRQ REV 150 %

N

Y

N

PID target value setting method

4-6

1 I-SEL

0: IN

F-43

PID IN-SEL IN

Y

A95

0

Y

Y

selection

PID target value setting

2 LVL

0.00 %

PID LVL 000.0 %

Y

A96

000

Y

N

P gain setting

3 P

1.0

PID P 1.0

Y

A90

1.0

Y

N

I gain setting

4 I

1.0 s

PID I 1.00 s

Y

A91

1.0

Y

N

D gain setting

5 D

10.0

PID D 0100.0

Y

A92

0.0

Y

N

PID selection

6 MODE

0: MDO

PID MODE MDO

Y

A94

0

Y

N

set
value