11.2 Individual Specification (USA version (J300-

LFU, HFU))

Item

Applicable
motor rating
(4P, max.
kW/HP)

(NOTE 1)

Continuous
output
(kVA)

Constant
torque

Rated output
current (A)

Description

Input voltage

Model Name (Type)

200 V class

400 V class

7.5/

10

11/

15

15/

20

22/

30

30/

40

37/

50

45/

60

55/

75

75/

100

7.5/

10

11/

15

15/

20

22/

30

30/

40

37/

50

45/

60

55/

75

75/

100

8.3 11 16 22 33 42 50 63 76

10 13 18 25 38 48 58 73 88

24 32 46 64 95

121145 182 220

13 16 23 32 48 58 75 90

110

150%, for 1 minute

Constant torque

Variable torque
(NOTE 2)

5.5/

7.5

7.5/

10

11/

15

15/

20

22/

30

30/

40

37/

50

45/

60

55/

75

5.5/

7.5

7.5/

10

11/

15

15/

20

22/

30

30/

40

37/

50

45/

60

55/

75

200 V

230 V

8.6

10.5

15 21 32 38 49 59 72

380 V

9.0 11 16 22 33 40 52 62 76

400 V

10.412.7

18 25 38 46 60 72 88

460 V

9 12 18 25 37 47 56 71 86

200 V

11 14 21 29 43 54 65 82 99

230 V

9.6

11.8

17 24 36 43 55 66 82

380 V

10.112.5

18 25 37 45 58 70 86

400 V

11.614.3

21 29 43 52 67 80 99

460 V

Variable
torque

Constant torque

Variable torque
(NOTE 3)

27 36 52 72

107

136 163 205 248 14.6

18 26 36 54 65 84

101124

Carrier
frequency
(Hz)

Constant torque

Variable torque
(NOTE 3)

12

10

6

10

16

16

Overload
current
capacity

Constant torque

Variable torque
(NOTE 3)

125%, for 1 minute

General
specifications

Ambient
tempera-
ture

-10 to 40 degree C

20 to 90% RH

Humidity

CT
(NOTE 4)
VT
(NOTE 5)

-10 to 50 degree C

The applicable motor is a Hitachi standard four-pole motor. When using another motor,
make sure that the rated motor current does not exceed the rated inverter current.
Applicable motor rating at variable torque is valid with the condition that output current
does not exceed the rating at variable torque.
When a V/F pattern (VP1, VP2, or VP3) for variable torque is selected (
for the digital operator or F04 for the remote operator), the setting data are automatically
changed by the inverter.
CT: Constant torque.
VT: Variable torque.

NOTE 1:

NOTE 2:

NOTE 3:

NOTE 4:
NOTE 5:

12

6

10

6

16

12

12

10

16

6

75/

100

90/

120

110/

150

90/

120

110/

150

132/

200

2

2

135 156 208

156180 240

89

103 137

94

108 144

108 124 166

103 118 158

108 118166

124 143191

055

LF

075

LF

110

LF

150

LF

220

LF

300

LF

370

LF

450

LF

550

LF

055

HF

075

HF

110

HF

150

HF

220

HF

300

HF

370

HF

450

HF

550

HF

750

HF

1100

HF

900

HF

2200

HF

1600

HF

1320

HF

132/

200

160/

250

220/

300

260/

350

160/

250

220/

300

3

2

158 207 250

166 218 263

191 251 303

240 315 380

302 380 435

199 250 286

209 263 301

241 303 347