beautypg.com

Hitachi J300U Series User Manual

Page 105

background image

12-14

Display

(Function mode 1)

(Function mode 2)

Setting, change

sequence

Function

Function

Initialization display

Initialization

contents

Setting contents

No.

name

contents

34

F-41

Position

PO EGRP

FB

FB

FB/REF

Effective with option board

Electronic setting

(J-FB)

gear

switching

setting

Numerator

PO EGR-N

00001

1

1 to 9999

of ratio
Denominator

PO EGR-D

00001

1

1 to 9999

Feed for-

PO FFWG

000.00

0

0 to 655.35

ward gain
Position

PO G

000.50 rad/s

0.5

0 to 100

loop gain

rad/s

35

F-42

Torque

TRQ LIMIT

REM

REM

REM/OP1/OP2

REM: Each operator

Torque

limit

PO1: Option 1

limit

setting

PO2: Option 2

setting

switching

(Note 1)

Plus torque

TRQ FWD

150%

150%

20 to 150%

limit
Minus

TRQ REV

150%

150%

20 to 150%

Regenerative mode

torque limit

36

F-43

PID target

PID IN-SEL

IN

IN

IN/OUT

PID control

value input

setting

method
switching
selection
PID target

PID LVL

000.00%

0%

0 to 200%

value setting
P gain setting

PID P

1.0

1.0

0.1 to 5.0

I gain setting

PID I

01.0S

1.0

0 to 15.0

D gain setting

PID D

000.0

000.0

0 to 100

Selection

PID MODE

MD0

MD0

MD0 to 4

37

F-46

Transmission

COM BAU 00600 bps

600

300/600/1200/

Effective with option board

Communi- speed

2400/4800/9600/

(J-CM)

cation

selection

19200

protocol

Station

COM NUMBER

01

1

1 to 32

setting

number
selection
Transfer bit

COM LENGTH

8

8

8/7

length
selection
Parity

COM PAR-SEL1

ON

ON

ON/OFF

ON / OFF
selection
Parity

COM PAR-SEL2 EVN

EVN

EVN/ODD

even / odd
selection
Stop bit

COM STOPBIT

2

2

2/1

length
selection

NOTE 1: Smaller levels of torque limit and overload restriction are given top priority and valid for any control

method.