beautypg.com

Hitachi J300U Series User Manual

Page 56

background image

7-16

Contents and display

Extension

function

code

1

2

FUNC

Speed
control
response
constant
setting

FUNC

.

.

.

1

2

.

.

1

2

Initial value

Set the response speed (ASR system gain) between the inverter and motor. When increasing
or decreasing the current motor response speed, adjust the ASR system gain. When the set value is
decreased, the response speed is increased. When the set value is increased, the response speed is
decreased.

A constant between 0.01
and 9.99 is set in units of 0.01.

A constant between 10.0
and 99.9 is set in units of 0.1.

A constant between 100
and 655 is set in units of 1.

Start
frequency
adjustment

Set the frequency for starting output of the inverter.
Set a frequency between 0.1 Hz and 9.99 Hz in units of 0.01 Hz.

2

1

1

2

FUNC

FUNC

.

.

,

,

.

V

f

0

0.10 9.99

Initial value

Output voltage

Maximum
frequency

Adjustment

range

When the start frequency is increased,
the acceleration or deceleration time is
decreased.