beautypg.com

A-31 – Hitachi J300U Series User Manual

Page 143

background image

A-31

Display with HOP, HRW Display with DOP, DRW

Function No. with digital operator

Data read/copy

Function mode

Layer

Data display

No.

Data display

Alterability

No.

Data

HRW DRW

Transmission speed selection

4-7

1 BAUD

1:600 bps F-46

COM BAUD 0600 bps

N

Y

N

Station number selection

2 NUMBER 1

COM NUMBER 01

N

Y

N

Bit length selection

3 LENGTH 0: 8

COM LENGTH 8

N

Y

Y

Parity ON/OFF selection

4 PAR-1

1: ON

COM PAR-SEL1 ON

N

Y

Y

Odd/even parity selection

5 PAR-2

0: EVN

COM PAR-SEL2 EVN

N

Y

Y

Stop bit length selection

6 STOPBIT 0: 2

COM STOPBIT 2

N

Y

Y

Relay output terminal RYA signal

4-8

1 RYA

3: RUN

F-48

RELAY RYA RUN

N

Y

N

selection

Relay output terminal RYB signal

2 RYB

0: CST

RELAY RYB CST

N

Y

N

selection

Relay output terminal RYC signal

3 RYC

4: OTQQ

RELAY RYC OTQ

N

Y

N

selection

Extension function setting

Setting only for digital operator

Y

F14

A 0

N

N

Voltage command adjustment

Setting only for digital operator

Y

A80

N

N

Current command adjustment

Setting only for digital operator

Y

A81

N

N

set