[Principle]

The acceleration and deceleration ratio or acceleration and deceleration are set in accordance
with the fuzzy rule from the distance to the overload restriction level and the start slopes of
current and voltage.

Acceleration ratio, acceleration
determination,deceleration ratio,
deceleration determination

Current

Revolution speed

Overload restriction level

Restriction angle

Distance

Slope

Time

Time

Setting process

The current grows.

Fuzzy control

Slope

Distance

Membership function