Hitachi J300U Series User Manual
Page 137

A-25
Appendix 7 List for display and data read/copy with each operators
(1) Monitor mode
Y: Possible
N: Not possible
Display with
Display with
Function No. with digital operator
Data read/copy
Monitor name
HOP, HRW
DOP, DRW
Alterability
No.
Data
HRW DRW
Frequency setting
First setting
FS
0.00 Hz FS0000.0
0.0 Hz
Y
F2
0.00
Y
Y
Second setting
FS
0.00 Hz FS0000.0
0.0 Hz
Y
F2
0.00
Y
N
Multistage speed setting
1S
0.00 Hz 1S0000.0
0.0 Hz
Y
F2
0.00
Y
N
(2)
7S
0.00 Hz 7S0000.0
0.0 Hz
Analog frequency setting
TM
0.00 Hz TM 0.0
0.0 Hz
Y
F2
0.00
N
N
(4)
Jogging frequency setting
JG
1.00 Hz JG 1.0
0.0 Hz
Y
F2
1.00
Y
Y
(5)
Option 1 frequency display
O1
0.00 Hz 01 0.0
0.0 Hz
Y
F2
0.00
Y
N
*1
(6)
Option 2 frequency display
O2
0.00 Hz 02 0.0
0.0 Hz
Y
F2
0.00
Y
N
*1
(7)
Output frequency setting
0.00 Hz FS0000.0
0.0 Hz
Y
d0
0.00
—
—
(8)
Acceleration time setting
First setting
AC1
30.00 s ACC1
0030.00 s
Y
F6
30.0
Y
Y
Second setting
AC1
30.00 s ACC1
0030.00 s
Y
F6
30.0
Y
N
2-step acceleration time setting AC2
15.00 s ACC2
0015.00 s
Y
F6
15.0
Y
N
Deceleration time setting
First setting
DC1
30.00 s DEC1
0030.00 s
Y
F7
30.0
Y
Y
Second setting
DC1
30.00 s DEC1
0030.00 s
Y
F7
30.0
Y
N
2-step deceleration time setting DC2
15.00 s DEC2
0015.00 s
Y
F7
15.0
Y
N
Motor pole number settingRPM
1:4 P RPM 4P
ORPM
Y
A25
4
Y
Y
Motor rpm monitored
ORPM
Y
d1
0.00
—
—
Converted frequency setting
/Hz
1.0 /Hz 01.0
0.00
Y
A47
1.00
Y
Y
Converted frequency monitor
0.00
Y
d3
0.00
—
—
Output current monitor
Im
0.0 A Im 0.0 A
0.0 %
Y
d2
0.00
—
—
Output current rate monitor
0.0 %
N
—
—
—
—
Torque monitor
Torque
0 % Torque
0 %
N
—
—
—
—
Manual torque boost adjustment
First setting
V-Boost
11 V-Boost
code<11>
Y
F8
11
Y
Y
Second setting
V-Boost
11 V-Boost
code<11>
Y
F8
11
Y
N
Manual torque boost frequency
adjustment
First setting
V-Boost
F 10.0 % V-Boost
F 10.0 %
N
—
—
Y
N
Second setting
V-Boost
F 10.0 % V-Boost
F 10.0 %
N
—
—
Y
N
Output voltage gain adjustment V-Gain
100 % V-Gain
100 %
N
—
—
Y
Y
Jogging frequency setting
Jogging
1.00 Hz Jogging
1.00 Hz
Y
A61
1.00
Y
Y
Analog meter adjustment
ADJ
172 ADJ
172
Y
F10
172
Y
N
Terminal input status monitor TERM
LLLLLLLLL TERM
LLLLLLLLL
N
—
—
—
—
Alarm display
First setting
WARN
# WARN
#
N
—
—
Y
N
*1 Represents an indication for commanding frequency from the optional PCB.
(13)
(14)
(15)
(16)
(17)
(18)
set
value