ORDERING INFORMATION

List Options

Order the following by the items Part Number as specified in the following table.

When viewing electronically, click on the List # to jump to the detailed description page.

List Options (Numbers)

List

No.

Part Number

Description

Mounting
Positions

(1U = 1-3/4”)

Notes

1

58112600001

Main Bay Common Equipment (Power and Distribution).
Accepts Distribution Cabinet (List 21, 22, 23, or 24) with
MCA (List 10, 11, 12, or 13) and Module Mounting
Assembly Interface (List 30).

-- 1,

2

2

58112600002

Supplemental Bay Common Equipment (Power and
Distribution). Includes interbay power busbars and
communication cable. Accepts Distribution Cabinet (List
23 or 24) and Module Mounting Assembly Interface (List
30).

-- 1,

2

4

58112600004

“Distribution Only” option for List 2 or 5. Configures the
bay for use without Module Mounting Assembly.

--

5

58112600005

Remote Supplemental Bay Common Equipment (Power
and Distribution). Includes communication cable.
Requires interbay power cabling. Accepts Distribution
Cabinet (List 21, 22, 23, or 24) and Module Mounting
Assembly Interface (List 30).

-- 1,

2

10

58112600010

MCA - Standard Application (Configuration No. 534876)
(installed in Main Bay Distribution Cabinet).

-- 1,

2

11

58112600011

MCA - Special Application (Configuration No. 534877)
(installed in Main Bay Distribution Cabinet).

-- 1,

2

12

58112600012

MCA - Special Application (Configuration No. 534878)
(installed in Main Bay Distribution Cabinet).

-- 1,

2

13

58112600013

MCA - Special Application (Configuration No. 534879)
(installed in Main Bay Distribution Cabinet).

-- 1,

2

21

58112600021

1-Row Distribution Cabinet (for use in List 1 and 5).

7U

1, 2

22

58112600022

2-Row Distribution Cabinet (for use in List 1 and 5).

11U

1, 2

23

58112600023

3-Row Distribution Cabinet (for use in List 1, 2, and 5).

15U

1, 2

24

58112600024

4-Row Distribution Cabinet (for use in List 1, 2, and 5).

19U

1, 2

29

58112600029

Top Shield for Distribution Cabinet.

--

--

30

58112600030

Interface Components for one (1) 588705101, 588705102,
588705103, or 588705104 Module Mounting Assembly.

2U to 8U

1, 2, 3

31

58112600031

Field Expansion Kit. Provides one (1) 588705100
8-Position Module Mounting Assembly and components
required for field installation in a Power System.

2U --

50

58112600050

Model R24-2500 Rectifier Module (PCU)
(for use in List 30 and 31).

-- 1,

2

60

58112600060

DC-DC Converter Option Interface Component Kit