List 62: DC-DC Converter Module

Features

♦ Provides one (1) Model C24/48-1500, Spec. No. 1C24481500, DC-DC

Converter Module.

♦ Refer to Power Data Sheet

PD588705100/PD588705101/PD588705102/PD588705103/
PD588705104 for more information.

Restrictions

For use in Spec. No. 588705100, 588705101, 588705102, 588705103, or 588705104 Module Mounting
Assemblies.

Requires

List 60

.

Supplemental Bays CANNOT have Converter Modules.

Ordering Notes

1) Order as required. Each 8-position Module Mounting Shelf holds up to four (4) DC-DC Converter

Modules when equipped with a DC-DC Converter Option Kit.

List 71: Optional Audible Alarm and Alarm Termination Circuit Card

Features

♦ Provides an Audible Alarm and Alarm Termination circuit card (P/N

509539). This circuit card is interconnected to the MCA and (via relays
on the circuit card) to external converter major and minor alarm circuits
(if converters are furnished). The circuit card provides spring-clamp
type terminals for connection of customer wiring to the MCA external
alarm circuits in lieu of the standard alarm cable.

♦ Includes a local audible alarm-sounding device connected to the external audible alarm contacts. The

audible alarm can be silenced locally.

Restrictions

Must be located in Main Bay (

List 1

) only.

Audible alarm is inoperative when used with List

12

or

13

MCA (no audible alarm relay contacts available).

Ordering Notes

1) Order per site requirements.

List 72: MCA Interface Modem Option

Features

♦ Provides a 2400 bits/s Modem circuit card, Spec. No. 486781300, plus associated

hardware.

♦ This option plugs into the MCA.
♦ Allows MCA interface via a modem port.
♦ See

also

WinLink Software (List 73)

.

Restrictions

Must be located in Main Bay (

List 1

) only.