beautypg.com

Mca interface ethernet, Mca interface – Emerson SAG581126000 User Manual

Page 29

background image

System Application Guide

SAG581126000

Spec. No. 581126000 (Model 700

NVBA

)

Issue AD, November 23, 2009

Page 29 of 123

This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy

Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

List 77: MCA Interface Ethernet Option:
WinLink Compatible + Web Interface + Battery Monitoring

Features

♦ Provides an Ethernet circuit card (P/N 524541) and associated mounting hardware.
♦ Ethernet circuit card is WinLink Compatible, provides a Web Interface, and provides

Battery Monitoring.

♦ This option plugs into the MCA.
♦ Allows MCA interface via an Ethernet port.
♦ See

also

WinLink Software (List 73)

.

Restrictions

Must be located in Main Bay (

List 1

) only.

Only one interface option (List

72

,

74

,

75

,

76

, 77, or

78

) can be installed.

The Ethernet card requires an MCA with firmware version 5.2.0 or later.

Ordering Notes

1) Order this option for each Power System (MCA) to be accessed via WEB Interface.

2) Order optional Front Access Ethernet Connector Kit P/N 525110, as required. This includes an RJ45

connector, mounting bracket, and jumper that mounts in the cutout provided on the front of the MCA
Panel.

3) WinLink Software (List 73) will operate with List 77 but is not required. Internal WEB Pages are preferred.

List 78: MCA Interface Ethernet Option:
WinLink Compatible + Web Interface + SNMP + Battery Monitoring

Features

♦ Provides an Ethernet circuit card (P/N 524541) and associated mounting hardware.
♦ Ethernet circuit card is WinLink Compatible, provides a Web Interface, provides

Battery Monitoring, and provides SNMP.

♦ This option plugs into the MCA.
♦ Allows MCA interface via an Ethernet port.
♦ See

also

WinLink Software (List 73)

.

Restrictions

Must be located in Main Bay (

List 1

) only.

Only one interface option (List

72

,

74

,

75

,

76

,

77

, or 78) can be installed.

The Ethernet card requires an MCA with firmware version 5.2.0 or later.

Ordering Notes

1) Order this option for each Power System (MCA) to be accessed via WEB Interface.

2) Order optional Front Access Ethernet Connector Kit P/N 525110, as required. This includes an RJ45

connector, mounting bracket, and jumper that mounts in the cutout provided on the front of the MCA
Panel.

3) WinLink Software (List 73) will operate with List 78 but is not required. Internal WEB Pages are preferred.

Home