System Application Guide

SAG581126000

Spec. No. 581126000 (Model 700

NVBA

)

Issue AD, November 23, 2009

Page 17 of 123

This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy

Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

13) Order as required additional options per Lists

29

,

71

, and

93

.

14) Order as required any additional accessories described under

ACCESSORY DESCRIPTIONS

.

List 2: Supplemental Bay Common Equipment (Power and Distribution)
(located next to Main Bay)

Features

♦ Provides common equipment for one bussed “power and distribution” bay rated for up to 2000 amperes of

distribution. Includes interbay power busbars and communications cabling.

♦ Mounts to either left or right side of a

List 1

Main Bay.

♦ Accepts one (1) Distribution Cabinet (options are 3-Row or 4-Row cabinet).
♦ Accepts one (1) Module Mounting Assembly. The Module Mounting Assembly can consist of one (1), two

(2), three (3), or four (4) factory interconnected 8-position Module Mounting Shelves. Each Module
Mounting Shelf in a Module Mounting Assembly provides eight (8) mounting positions for Rectifier
Modules (PCUs).
or
Can be configured for “distribution only” (no Module Mounting Assembly).

Restrictions

Order maximum of one (1) List 2 or

List 5

per Power System.

Cannot be used when List 5 is ordered. Order List 2 or List 5, not both.

Supplemental Bays DO NOT accept Converter Modules. DO NOT order List

60

or

62

for Supplemental Bays.

List 2 Supplemental Bay DOES NOT accept List

21

or

22

Distribution Cabinet

(List 21 and 22 are not provided with connection points for interbay busbars.)

Rear access is required for installation of inter-bay busbars.

Ordering Notes

1) Order a relay rack per '

Relay Racks

' under ACCESSORY DESCRIPTIONS. If required, order Relay Rack

Transition Plates per '

Transition Plates to Mount Relay Rack P/N 543156 on Top of GNB Absolyte IIP

Batteries

' under ACCESSORY DESCRIPTIONS. Relay rack must be same height as relay rack ordered

for

List 1

. A ship loose option is available, as described in '

Relay Racks

' under ACCESSORY

DESCRIPTIONS.

2) Order one (1) List

23

or

24

Distribution Cabinet.

3) Order up to four (4) Distribution Bus Panels as required per '

Distribution Bus Arrangements

' and the

capacity of the Distribution Cabinet ordered.

4) Order one (1) List

30

(interface components for one (1) Module Mounting Assembly). Order a Module

Mounting Assembly per PD588705101/PD588705102/PD588705103/PD58805104. List 30 is factory
connected to the Module Mounting Assembly ordered.
or
Order Supplemental Bay 'Distribution Only' option per List

4

.

5) Order Rectifier Modules (PCUs) per List

50

as required.

6) Order one (1) Module Mounting Position Blank Cover Panel,

Part No. 540959

, for each empty module

mounting position in the system.

7) Order fuses and/or circuit breakers, as required, per '

Distribution Devices

' under ACCESSORY

DESCRIPTIONS.

8) Order input and load distribution lugs, as required, per '

Wiring Components

' under ACCESSORY

DESCRIPTIONS.