beautypg.com

SMA Sunny Data Control V.5.0 User Manual

Page 63

background image

Displaying Data

SMA Technologie AG

Technical Description

SDC-TEN081450

65

The "Device Type Selection" window opens.

4.

Select the desired device types and use the arrow buttons to copy them into the "Selected
device types" field or to move them using "drag and drop".

5.

Click on .

The "Settings" window is displayed once more.

Configuring the Total Overview Display

6.

Check on the values which should be displayed (e.g., "Display total output", "Display energy
produced today").

7.

Configuring the Total Overview Display

The following settings are possible.

Text:

Here, you can type in a text for the display (e.g. "Pac" for the total output, and "E-total" for the
total yield).

Unit:

Here, you can choose between the units W, kW and MW in the drop-down list.

Format:

Here, you can set the number of decimal places with which the values are to be displayed (#
= no decimal places... #.### = three decimal places).

Factor:

Here, you can enter a factor by which the calculated value is to be multiplied.

Offset:

Here, you can enter a corrective value which is to be added to the calculated value.