Transferring Data to the Internet
SMA Technologie AG
112
SDC-TEN081450
Technical Description
Configuring the Server Port and Channel Scan
The server port setting specifies the TCP port at which the server awaits queries from the SDC agent.
By default, this is set to port 18503.
The channel scan setting is the time waited (in seconds) between sending two channel updates.
8.
If necessary, make the appropriate adjustments to the server port and channel scan settings.
9.
Deallocate the router as described in its manual or contact the network administrator.
Offline Server
The setting "Offline Server" makes it possible to choose between direct connection and offline
connection of the PV plant. See section 12.6. 1 "Overview" (Page 108).
10. Add or remove the check mark beside "Offline Server", according to whether or not your
Sunny Boy Control is directly connected to Sunny Data Control.
Server is Active
11. Activate the server = check "Server is active".
Dectivate the server = uncheck "Server is active".
You can only make changes and adjust settings for the respective Internet channel if the check
mark beside "Server is active" is first removed.
12. Click on
Consult the network administrator.
Only alter the server port and channel scan settings if you fully understand the
consequences of the changes. Incorrect settings can result in the SDC agent no longer
functioning.
If your Ethernet network is managed by a network administrator, contact this
administrator so that the appropriate port on the router can be enabled.