beautypg.com

SMA Sunny Data Control V.5.0 User Manual

Page 24

background image

Connecting the PC to a Communication Device

SMA Technologie AG

26

SDC-TEN081450

Technical Description

Sunny Boy Control / Plus

8.

Plug the 9-pin D-Sub female connector into the
port on the Sunny Boy Control which is
equipped with the RS485 interface.

(A) Sunny Boy Control: PC (COM 2)

(B) Sunny Boy Control Plus: PC (COM 2) or
AUX (COM 3)

9.

Connect the PC's Data+ with the Data+ of the
Sunny Boy Control / Plus, and so on. The 3
connections should be made directly.

Use listed cable colors.

Termination

10. On the last Sunny Boy Control / Plus in the 485

data bus, Jumper A should be plugged into the
interface being used.

11. Jumper A must not be plugged into the used

interface on any of the other
Sunny Boy Control / Plus devices.

12. Remove any jumpers A, B or C which may be

plugged, from the interfaces used.

A

B

A

B