Grass Valley GV STRATUS Playout v.2.0 User Manual
Page 71

71
GV STRATUS Playout
Operator Manual
Fig. 3-7: Example of the System Administration page for downloading the File Processing Node
4 If you do not have the listed prerequisite software installed, click Install. Otherwise,
click launch to open the File Processing Node application.
5 Before you can proceed, you must register the File Processing Node application as a
device in GV STRATUS Playout, but you do not need to assign it to a channel. For more
information, see
, on page 44. Copy the key provided for the device.
6 Once you have created the device in GV STRATUS Playout, you need to provide the key
to the File Processing Node application so it can register itself with the device that you
created. To complete the registration, provide the required information in the Enter
registration code dialog box:
• In the Deployment list, click the name of the deployment to which you are
registering the File Processing Node application.
• In the Code field, paste or type the key provided by GV STRATUS Playout when you
created the device.
• Click OK.
7 Verify that the registration was completed. In GV STRATUS Playout open the Settings >
Device Settings page and find the device you created in the Devices list and verify that
it no longer shows as PENDING in the IP column. It should display the IP address of the
computer where the File Processing Node application is installed.
Setting up a job to convert a media file to compatible format
The File Processing Node can run multiple processing jobs in parallel depending on the
capabilities of the host computer or you can install and register File Processing Node
applications on different computers in the network to build a media rendering farm.
Settings page
System Administration tab
Download the File Processing Node