beautypg.com

Epson Power Supply S1F70000 User Manual

Page 214

background image

S1F77200Y Series

5–14

EPSON

S1F70000 Series

Technical Manual

S1F77210Y1F0

(Ta = –30

°

C to +85

°

C is assumed except where otherwise specified.)

Parameter

Symbol

Conditions (V

SS

= 0.0V)

Min.

Typ.

Max.

Unit

Operating voltage

V

DD

1.50

12.0

V

Detection voltage

V

DET

Ta = 25

°

C

2.60

2.65

2.70

V

Hysteresis width

V

HYS

V

HYS

= V

REL

– V

DET

0.05

0.10

0.15

V

Operating current

I

DD

V

DD

= 3.0V

2.00

5.00

µ

A

Detection voltage

V

DET

–300 –100 +100

ppm/

°

C

temperature characteristics

V

DET

High level output current

I

OH

V

DD

= 2.0V

–0.40 –0.10

mA

OUT = 1.8V

Low level output current

I

OL

V

DD

= 3.0V

0.50

2.00

mA

OUT = 0.3V

V

DD

= 3V

2V

8

40

µ

s

Detection voltage

T

PHL

Ta = 25

°

C

response time

V

DD

= 3V

2V

200

µ

s

Ta = –30

°

C to +85

°

C

S1F77200Y1T0

(Ta = –30

°

C to +85

°

C is assumed except where otherwise specified.)

Parameter

Symbol

Conditions (V

SS

= 0.0V)

Min.

Typ.

Max.

Unit

Operating voltage

V

DD

1.50

12.0

V

Detection voltage

V

DET

Ta = 25

°

C

3.90

4.00

4.10

V

Hysteresis width

V

HYS

V

HYS

= V

REL

– V

DET

0.13

0.20

0.27

V

Operating current

I

DD

V

DD

= 5.0V

2.00

5.00

µ

A

Detection voltage

V

DET

–300 –100 +100

ppm/

°

C

temperature characteristics

V

DET

Low level output current

I

OL

V

DD

= 2.0V

0.20

1.00

mA

OUT = 0.2V

V

DD

= 5V

4V

8

40

µ

s

Detection voltage

T

PHL

Ta = 25

°

C

response time

V

DD

= 5V

4V

200

µ

s

Ta = –30

°

C to +85

°

C