S1F77200Y Series

5–12

EPSON

S1F70000 Series

Technical Manual

S1F77210Y120

(Ta = –30

°

C to +85

°

C is assumed except where otherwise specified.)

Parameter

Symbol

Conditions (V

SS

= 0.0V)

Min.

Typ.

Max.

Unit

Operating voltage

V

DD

1.50

12.0

V

Detection voltage

V

DET

Ta = 25

°

C

4.50

4.60

4.70

V

Hysteresis width

V

HYS

V

HYS

= V

REL

– V

DET

0.08

0.15

0.22

V

Operating current

I

DD

V

DD

= 5.0V

2.00

5.00

µ

A

Detection voltage

V

DET

–300 –100 +100

ppm/

°

C

temperature characteristics

V

DET

High level output current

I

OH

V

DD

= 5.0V

–2.00 –0.50

mA

OUT = 4.5V

Low level output current

I

OL

V

DD

= 2.0V

0.20

1.00

mA

OUT = 0.2V

V

DD

= 5V

4V

8

40

µ

s

Detection voltage

T

PHL

Ta = 25

°

C

response time

V

DD

= 5V

4V

200

µ

s

Ta = –30

°

C to +85

°

C

S1F77210Y1K0

(Ta = –30

°

C to +85

°

C is assumed except where otherwise specified.)

Parameter

Symbol

Conditions (V

SS

= 0.0V)

Min.

Typ.

Max.

Unit

Operating voltage

V

DD

1.50

12.0

V

Detection voltage

V

DET

Ta = 25

°

C

4.70

4.80

4.90

V

Hysteresis width

V

HYS

V

HYS

= V

REL

– V

DET

0.13

0.20

0.27

V

Operating current

I

DD

V

DD

= 5.0V

2.00

5.00

µ

A

Detection voltage

V

DET

–300 –100 +100

ppm/

°

C

temperature characteristics

V

DET

High level output current

I

OH

V

DD

= 5.0V

–2.00 –0.50

mA

OUT = 4.5V

Low level output current

I

OL

V

DD

= 2.0V

0.20

1.00

mA

OUT = 0.2V

V

DD

= 5V

4V

8

40

µ

s

Detection voltage

T

PHL

Ta = 25

°

C

response time

V

DD

= 5V

4V

200

µ

s

Ta = –30

°

C to +85

°

C