beautypg.com

Absolute maximum ratings, Epson, Power off function – Epson Power Supply S1F70000 User Manual

Page 182

background image

S1F71100 Series

S1F70000 Series

EPSON

4–37

Technical Manual

S1F71100

Series

Power Off Function

S1F71100 can control circuit operations according to
external signal control. When the POFFX pin is con-
nected to the V

SS

level, all circuits stop their operations

and their powers are turned off. The current consump-
tion at the power off state is less than 1

µ

A. When the

power is off, the SWO pin is at the V

DD

level and turns

off the voltage transistor. The voltage at the SSCAP pin

ABSOLUTE MAXIMUM RATINGS

Parameter

Symbol

Applicable Pin

Rated Value

Unit

Input voltage

V

DD

V

DD

15.0

V

Voltage at V

O

pin

V

O

V

O

V

SS

–0.3 to V

DD

+0.3

V

Voltage at POFFX pin

POFFX

POFFX

V

SS

–0.3 to V

DD

+0.3

V

Voltage at ERCAP pin

ERCAP

ERCAP

V

SS

–0.3 to V

DD

+0.3

V

Voltage at SSCAP pin

SSCAP

SSCAP

V

SS

–0.3 to V

DD

+0.3

V

Voltage at SWO pin

SWO

SWO

V

SS

–0.3 to V

DD

+0.3

V

Voltage at I

SENSE

pin

I

SENSE

I

SENSE

V

SS

–0.3 to V

DD

+0.3

V

Package allowable loss

P

D

P

D

300

MW

Ta

25˚C

Operating temperature

Topr

–30 to +85

˚C

Storage temperature

Tstg

–55 to +150

˚C

Soldering temperature and time

Tsol

260 · 10

˚C·S

Note :Any operation under conditions exceeding the above absolute maximum ratings may result in a malfunc-

tion or a permanent destruction. When even an item is more than the rating, a temporary normal operation
is possible but with remarkably low reliability. So, be sure to keep all items below the ratings.

comes to the V

SS

level, and the output voltage is con-

trolled with the soft start circuit after the power off state
is released. In the operating state, set the POFFX pin to
the V

DD

level to operate it. The POFFX pin cannot be

operated in a open state. When the power off function is
not used, connect the POFFX pin to the V

DD

pin.