beautypg.com

2 − names and functions of parts – Teac HS-2000 User Manual

Page 17

background image

TASCAM HS-2000

17

2 − Names and functions of parts

9

AES31 file name (button)
This shows the name of the currently loaded AES31 file

(AES31 editing information file).

A “*” appears in the icon when the file has not been

saved after timeline editing, a mark has been added or

removed, or other changes have been made.

Touch this area to open a pull-down menu.

START TIME EDIT button

Opens the

START TIME

screen where you can set

the timeline mode starting time.
This can only be selected when the transport is

stopped.

REBUILD button

Rebuilds the additional index files for HS-2000 when

files have been deleted or modified remotely using

FTP, for example.
This can only be selected when the transport is

stopped.

SAVE button

Saves the contents of the timeline.
This can only be selected when the transport is

stopped.
(See “Saving AES31 editing information” on page 53.)

SAVE AS button

Allows you to rename and save the contents of the

timeline.
This can only be selected when the transport is

stopped.
(See “Naming and saving AES31 editing information”

on page 53.)

CREATE AES31 button

Open the

AES31 NAME

screen to create a new

AES31 file.
This can only be selected when the transport is

stopped.
(See “Creating new AES31 editing information” on

page 54.)

IMPORT ALL TAKES button

Use to import all takes in a session.
This can only be selected when the transport is

stopped.
(See “Importing all takes” on page 55.)

0

Input monitoring indicators
The left ends of the level meters are input monitoring

indicators. Their background colors depend on the

input monitoring status, as shown below.

Playlist mode Timeline or

take mode

MON OFF

MON ON

q

Level meters
When input monitoring is ON, the input signal level is

shown when in recording standby or when recording.

Each channel also has an overload indicator at its right

end that appears red when the input signal reaches an

overload level.

During playback, the playback level is shown if input

monitoring is OFF.

When a digital input is selected as the source, but

there is no input signal or if the actual input signal

differs from the internal settings, the channel meter

display area appears gray and one of the following

messages appears.

Message

Meaning

D-IN NO SIGNAL

No input signal

D-IN UNLOCK

Input signal is not synchronized

with the system

D-IN NOT AUDIO

Cbit information of the input signal

is not audio

D-IN Cbit ERROR

Other input signal Cbit information

differs from the actual operation

mode

D-IN NO SIGNAL message

The following level meter display settings can be made

on the

METER SETUP

page of the

MENU

screen.

Metering point

Peak hold time

Release time

Overload indicator peak level

Reference level line display on/off