11 – Internal settings

ANALOG Ref LVL ADJUST page

You can make fine adjustments to the analog input and

output reference levels for each channel independently.

Use an IN X knob (“X”is L or R) to adjust the analog

input level of the corresponding channel, and use an

OUT X knob to adjust the analog output level of the

corresponding channel.

Touch a knob to select it, making its area yellow, and use

the DATA dial to adjust the level.

Turn the dial to adjust it in 0.1dB intervals, and press

and turn the dial to adjust it in 1dB intervals. The value is

shown beneath each knob.

Setting range: –6dB to +6dB (default: 0dB)

If the

INPUT SOURCE

on the

INPUT

tab of the

AUDIO I/O

screen is set to Digital instead of Analog,

the corresponding knob will not be shown and “Analog IN

not selected” will appear in the menu area.

Not set to analog input

Backup/Startup page

You can import and export system files, save and load user

settings, and set the startup mode using the

Backup/

Startup

page of the

SYSTEM SETUP

screen.

System Backup

8

Use the Export button to write all System Backup data

(including User Preset settings) to the selected card.

Only one set of System Backup data can be saved on a

card.

Use the Import ALL button to load all System Backup

data (including User Preset settings) from the selected

card and overwrite the built-in memory with it.

The imported User Preset settings are immediately

applied to the operation of the unit.

Use the Import User button to import only the User

Preset settings from the System Backup data on the

selected card and overwrite the User Preset in the

built-in memory with it.

Imported User Preset settings are not immediately

applied to the operation of the unit. After importing,

touch the LOAD Preset User button to apply the User

Preset settings.

If there are no System Backup files, a pop-up window

indicating that the import cannot be performed

appears.

Save User Preset

8

Press the Save button save the current setting values

as the User Preset in the built-in memory.

Load Preset

8

Touch the User button to load the User Preset

settings or the Factory button to load the Factory

Preset settings (the values when first shipped new).

Startup MODE

8

Last Setting : Load previous settings when turned on
User Preset : Load User Preset settings when

turned on

Factory Preset : Load Factory Preset settings when

turned on