Message

Details and responses

Notes

Cannot RECORD
Play Fs setting is not OFF.
Please change Play Fs to OFF.

Recording is not possible because Play Fs is set to Pull-down or Pull-up.

Cannot RECORD
System limit reached.
Please make new Session.

The total number of items in the folder, including files and folders/directories, is
too large, so starting recording is not possible.

Cannot RECORD.
Take limit reached.
Please change to another Session

Since the maximum number of recordable takes or maximum take number has
been reached, recording is not possible. Change the session.

Cannot Retake.
No Recent REC history.

You cannot retake until at least one recording has been made in this session.

Cannot set Mark point
in ON AIR Mode.

Marks cannot be added in on-air mode.

Cannot set Mark point.
Mark limit reached.

You cannot create more than 99 marks.

Cannot turn Fs convert On.
D-In is already
Master Clock.

You tried to turn the sampling rate converter on for the digital input that is set as
the master clock.

Cannot use Bridge file
because it is illegal.

Cannot use the bridge file because it is not correct.

Capture BC$ Time to ALL?
BC$STANDBY -> Start
BC$END

-> End

Confirm that you want to use the BC$STANDBY and BC$END mark times for all
entries.

Capture BC$ Time?
BC$STANDBY -> Start
BC$END

-> End

Confirm that you want to use the BC$STANDBY and BC$END mark times.

CFn(vvvvvvvv)

Fs: fs

USED SIZE: u
FREE SIZE: f
TOTAL SIZE: t

This shows information about the CF card in on-air mode.

n = 1 or 2
vvvvvvvv = volume level
fs: the current Fs setting
u: capacity used
f: capacity unused
t: CF card total capacity

CF1 Media Full.

CF1: Stopped.
CF2: Still RECORDING.

Since CF card 1 does not have enough open space, recording to it has stopped.
Recording to CF card 2 continues.

This occurs when REC Mode is set to Mirror.

CF2 Media Full.

CF1: Still RECORDING.
CF2: Stopped.

Since CF card 2 does not have enough open space, recording to it has stopped.
Recording to CF card 1 continues.

This occurs when REC Mode is set to Mirror.

CFn not recommended
for Recording/Search.
(not Ultra DMA)

This CF card does not meet the specifications required by the system, so using it for
recording/searching is not recommended.

n = 1 or 2

CF1 Record Error.

CF1: Stopped.
CF2: Still RECORDING.

Since an error occurred during recording to CF1, recording to it has stopped.
Recording to CF card 2 continues.

This occurs when REC Mode is set to Mirror.

CF2 Record Error.

CF1: Still RECORDING.
CF2: Stopped.

Since an error occurred during recording to CF2, recording to it has stopped.
Recording to CF card 1 continues.

This occurs when REC Mode is set to Mirror.

Change Fs to nnkHz?

The system sampling frequency will be switched to the frequency shown.

nn: sampling frequency

Clear Current EDL and
Import All Takes?

Confirm that you want to clear the current AES31 editing data and import all the
takes.

Clear In/Out Point?

Confirm that you want to clear the IN and OUT points.

Combine these Takes?
"aaaaaaaa"
"bbbbbbbb"

Confirm that you want to combine the two takes.

aaaaaaaa = name of first take to be combined
bbbbbbbb = name of second take to be
combined

Completed

The operation has completed.

Confidence Monitor is not available
while REC Mode is Mirror.

When REC Mode is set to Mirror, confidence monitoring cannot be turned ON.

Confidence Monitor is not available
with current Fs.

Confidence monitoring cannot be turned ON because it is not supported with the
current Fs setting.