ATM_INQ
% Carbon Inquiry
N/A
Atmosphere
level
Wait, Wait Up,
Wait Down
121
MV_INQ
Millivolt Inquiry
N/A
Millivolt level
Wait, Wait Up,
Wait Down
122
PIDLOAD
Load PID Set
Loop 2 Set
Loop 1 Set
Loop 3 Set
123
SETVALVE
Set valve setpoint
Setpoint
Trim range
Valve number (0-
3)
124 SETBP
(SETLP3)
Set back pressure
(loop 3) setpoint
Setpoint N/A N/A
125
SETFCM
Set flow control
mode (Nitrider)
N/A N/A
Control
mode
126
IN_INQ
Input inquiry
Input value
Which Input
Wait, Wait Up,
Wait Down
127
CC_SP_L
Set setpoint limits
for cascade
SP lower limit
SP upper
limit
N/A
128 TC_CHK
Activate
or
deactivate TC check
Source 1
Source 2
Source 3
129
SET_SL_VAL
Set slave value
Data value
Register
number
Instrument
number
130
PLC_SET_VAL
PLC set value
Data value
Register
number
None, Wait, Wait
Up, Wait Down
131
OGholdm
Out gas hold micron
N/A
Micron level
Gage; 0 turns off
else gage 1,2,3,
or 4
132
Ogholdt
Out gas hold torr
N/A
Torr level
Gage; 0 turns off
else gage 1,2,3,
or 4
133
VLUP_ch
Vacuum leak up
check
Test pass step
Test retry
step
Test fail step
Notes About Opcodes
1. A Temperature column value of –301 disables the temperature data.
2. A vacuum column value of –1 disables the vacuum data column for non-vacuum
opcodes.
3. Temperature PO (percent output) values for HIGH_PO, LOW_PO, and PO_INQ are offset
by a value of –200, i.e., -300 to –100 represents –100 to 100.
4. Atmosphere PO (percent output) values for HIGH_PO, LOW_PO, and PO_INQ are offset
by a value of +100, i.e., 0 to 200 represents –100 to 100.
5. Wait is until in band, Wait up and Wait down are until value is reached +/- 1.
6. GRAMP is the same as RAMP, except that the temperature must be in band for GRAMP.
7. Load TCs can hold RAMP if they are enabled.
8. GSOAK is the same as SOAK, except that the temperature must be in band for GSOAK.
9. RAMPR uses a rate specification instead of time. This applies only to temperature.
10. GLSOAK is the same as GSOAK, except that only the low band limit applies, i.e., PV > SP
– limit.
11. GHSOAK is the same as GSOAK, except that only the high band limit applies, i.e., PV <
SP + limit.
12. The Max hold time in the vacuum column overrides the default max hold time for the
current step only.
13. The multiple event opcodes use a bit map mask to identify what events are addressed,
and a bit for the OFF/ON state of those events.