Analog output setup – Super Systems PC Configurator 2 User Manual
Page 169
Super Systems Inc.
Page 169 of 201
Configurator Manual #4562 Rev D
High Input Limit Hysteresis:
This is the setpoint for the high input limit. The range is –32768 to 32768.
Analog Output Setup
Configurator – Analog Output Setup menu option
The 9220 controller has the option of two analog outputs. The outputs are ranged for a 4 – 20
milliamp signal or a 0 – 20 milliamp signal. Each output comes with a factory default
configuration dependent on the application. Each output can be modified prior to shipment to
your facility or in the field by a supervisor.
Analog Output Terminals:
Analog output 1 – terminals 24 and 25
Analog output 2 – terminals 25 and 26
Assignment:
The analog output assignment can be modified depending on your system requirements. To
change the Assignment first select which analog output you want to change by selecting it in
the pull-down menu just below the main menu list. Clicking on this value will display an input
box, and then you can use the pull-down menu to select the desired parameter. Once selected
click OK
and the displayed assignment under Value will be the current assignment type. The
following is a list of the options:
PV 1 retrans
PV3 retrans
G1 linear torr
G4 log of torr
Loop 1 inc
Loop 3 inc
G1 microns
G4 linear torr
Loop 1 dec
Loop 3 dec
G2 log of torr
G4 microns
Loop 1 combo
Loop 3 combo
G2 linear torr
Programmer ID num
PV 2 retrans
Input 1 retrans
G2 microns
Loop 2 inc
Input 2 retrans
G3 log of torr
Loop 2 dec
Input 3 retrans
G3 linear torr
Loop 2 combo
G1 log of torr
G3 microns