Vacuum group, Spp2 group – Super Systems PC Configurator 2 User Manual
Page 178

Super Systems Inc.
Page 178 of 201
Configurator Manual #4562 Rev D
81
DELAY
Short delay
N/A
N/A
Delay time in seconds
82
DOW_INQ Day of week inquiry
N/A
N/A
SUN, MON, TUE,
WED, THU, FRI, SAT
83 G_SOAK
Guaranteed soak
(temperature)
N/A
Max hold time
Soak time in
hours:minutes
84 GHSOAK
GSOAK, high limit
only
N/A
Max hold time
Soak time in
hours:minutes
85 GLSOAK
GSOAK, low limit
only
N/A
Max hold time
Soak time in
hours:minutes
86
TOD_INQ
Time of day inquiry
N/A
N/A
Time in 24 hour form
(hours:minutes)
87 GTCINQDEL
Guaranteed TC
inquiry delay
Delay time
Control TC or load
TCs
Wait, wait up, wait
down
88 GZ_SOAK
Guaranteed soak
(TC zone)
N/A
Max hold time
Soak time in
hours:minutes
89 GHZSOAK
GSOAK, high limit
only, zone
N/A
Max hold time
Soak time in
hours:minutes
90 GLZSOAK
GSOAK, low limit
only, zone
N/A
Max hold time
Soak time in
hours:minutes
Vacuum Group
Value Opcode
Description
Temperature Atmosphere
Option
100
RLY_INQ
Relay state inquiry
Off step
On step
Gage/ABC
101 RLY_SP_M
Relay setpoint in
Micron
ON setpoint in
Micron
OFF setpoint in
Micron Gage/ABC
102
RLY_SP_T
Relay setpoint in Torr ON setpoint in Torr
OFF setpoint in
Torr Gage/ABC
103 VAC_INQ_M_1
Vac inquiry in Micron
gage 1
N/A
Micron level
Wait, wait up, wait
down
104 VAC_INQ_M_2
Vac inquiry in Micron
gage 2
N/A
Micron level
Wait, wait up, wait
down
105 VAC_INQ_M_3
Vac inquiry in Micron
gage 3
N/A
Micron level
Wait, wait up, wait
down
106 VAC_INQ_M_4
Vac inquiry in Micron
gage 4
N/A
Micron level
Wait, wait up, wait
down
107 VAC_INQ_T_1
Vac inquiry in Torr
gage 1
N/A
Torr level
Wait, wait up, wait
down
108 VAC_INQ_T_2
Vac inquiry in Torr
gage 2
N/A
Torr level
Wait, wait up, wait
down
109 VAC_INQ_T_3
Vac inquiry in Torr
gage 3
N/A
Torr level
Wait, wait up, wait
down
110 VAC_INQ_T_4
Vac inquiry in Torr
gage 4
N/A
Torr level
Wait, wait up, wait
down
SPP2 Group
Value Opcode
Description
Temperature Atmosphere Option