Communications setup – Super Systems 9205 Series User Manual
Page 37

Series 9205 Operations Manual Rev A
36
Communications Setup
Warning: Changes to this screen should not be made
without consulting SSi at 513-772-0060. This screen will
show the Ethernet and RS-232/RS-485 communications
information for the 9205 controller.
Note about ADAM module support: Communications with
ADAM analog input modules manufactured by Advantech
are not supported as of 9205 firmware revision 2.34. To
determine the firmware version of your 9205 instrument,
use the
About
option in the main menu.
IP Address
This will identify the IP address of the controller. Please
consult your Systems Administrator before changing this
value as it can affect communications to the 9205 controller, communications between the controller and
the PLC, communications between the controller and other devices on the network, or to data collection
systems. This is necessary if the Touchscreen will be communicating to the 9205 over Ethernet
communications. The IP address must be in the “xxx.xxx.xxx.xxx” format. NOTE: The IP address is not
typically used for communications from the touch screen to the controller, but for communications
between the controller to SuperDATA modules, PLCs, etc.
IP Mask
This will identify the Subnet mask of the controller. The Subnet mask must be in the “xxx.xxx.xxx.xxx”
format.
IP Gateway
This will identify the IP gateway of the controller. The IP gateway must be in the “xxx.xxx.xxx.xxx” format.
RS-232B Baud
This will set the baud rate for RS-232 communications. This is necessary if the Touchscreen will be
communicating through the Com ports. The list of options is:
1200
14400
57600
460800
2400
19200
76800
921600
4800
28800
115200
9600
38400
230400
RS-232B Mode
This will set the mode for RS-232 communications. This is necessary if the Touchscreen will be
communicating through the Com ports. The list of options is:
Modbus/no PLC
Modbus master/PLC
Host 485 (3,4) Baud
This will set the baud rate for RS-485 communications. This is necessary if the Touchscreen will be
communicating through the Com ports. The list of options is:
1200
14400
57600
460800
2400
19200
76800
921600
4800
28800
115200
9600
38400
230400