Programmer description, Wait, Rogrammer – Super Systems 9205 Series User Manual
Page 132: Escription

Series 9205 Operations Manual Rev A
131
Programmer Description
The Series 9205 Recipe Programmer provides a convenient operator interface and recipe
programmer.
The programmer uses enhanced opcodes that reduce the number of steps required for a program.
Each step may consist of: an opcode, a temperature value column, an atmosphere value column,
and an option value column. The opcode determines how and if each of the three values is used.
An explanation of wait, wait up, and wait down options can be found at the end of this chapter.
Each opcode will be listed in the following format for readability:
Opcode
Temperature Value Column
Atmosphere Value Column
Option Value Column
Description
Wait
When using the option wait with a set point Opcode, the recipe will not advance to the next step until the PV
value falls within the wait limit band. The upper limit of this band is value of the PV set point plus the wait
limit. The lower limit of this band is the value of the PV set point minus the wait limi. The wait limit band is
the range between the upper limit and the lower limit. The recipe will then continue to the next step.