Set menu security, Curve entry, Ecurity – Super Systems 9205 Series User Manual
Page 116: Urve, Ntry

Series 9205 Operations Manual Rev A
115
Set Menu Security
The Set Menu Security menu option is a feature that is used to limit access to certain menu options and
parameters that are vital to successful operation and communication of your instrument. This page comes
pre-configured by Super Systems Inc. and should not be adjusted without consulting SSi. The options are
operator, supervisor, or administrator.
Curve Entry
Most types of inputs that are used in SSi controllers
are already setup with a curve built for most every
type of thermocouple available, certain vacuum
sensors, etc. However, if an application calls for an
input without a standard curve, the curve can be
built using this option. Voltages can be paired with
corresponding values to create a sensor curve
based off of a provided equation or data. This allows
the controller to make appropriate readings from
the sensor.
The first screen shows that five separate curves can
be edited. Selecting one of Curve 1-5 and pressing
Edit will display the screen where new curves can
be assigned. The type can be toggled between
Linear and None.
Thirty-two points can be assigned by selecting one
of the points and pressing Edit. This allows the
operator to change the Millivolts and the
corresponding Value by clicking on each option.
Note that all 32 points do not need to be entered;
however, the more points that are entered, the more precise the calculated value will be. Any values that
are not entered should be set to values beyond (above or below) the ranges entered.
Curve Type
This is the type of curve. The options are none or linear.
Control Range
This is the control range for the curve. The range is 0 to 32000.
mV
X
(1 – 32)
Clicking on this value will display an input box from which the user can select a new millivolt value. The
range is from 0 to 32000.
Vac
X
(1 – 32)
Clicking on this value will display an input box from which the user can select a new vacuum value. The
range is from 0 to 32000.