Super Systems 9205 Series User Manual
Page 158

Series 9205 Operations Manual Rev A
157
The Time is the total time for the program to reach the desired setpoint(s), in Hours:Minutes format. The
Hours range from 0 – 166, and the Minutes range from 0 – 59.
The band limit can be changed by the
SET_WAIT
opcode.
GTCINQDEL
Delay Time
T/C
Option
This is a guaranteed TC inquiry short delay opcode. It is used to verify that all active thermocouples are
within the set wait limits around the setpoint for the user defined time period.
The Delay Time is the time in seconds before checking the T/Cs. The range is 0 – 500.
The T/C is the Control T/C or Load T/C to use. The options are: Control T/C, T/C 1 – T/C 24.
The Option will allow the user to wait for the T/Cs to come within the set wait limits around the setpoint.
The options are: Wait, Wait Up, or Wait Down.
GZ_SOAK
N/A
N/A
Soak Time
This is a guaranteed soak opcode for a zone. The temperature process value must be within the deviation
band to allow the soak timer to run. If the temperature process value goes out of the deviation band, then
the soak timer will stop and wait until the temperature process value comes back into the deviation band
before starting up again.
The Soak time is the total time, in Hours:Minutes format, for the soak to run. The Hours range from 0 –
166, and the Minutes range from 0 – 59.
The band limit can be changed by the
SET_WAIT
opcode.
GZDELAY
N/A
N/A
Delay Time
This is a guaranteed short delay opcode for a zone. The temperature process value must be within the
deviation band to allow the delay timer to run. If the temperature process value goes out of the deviation
band, then the soak timer will stop and wait until the temperature process value comes back into the
deviation band before starting up again.
The Delay Time is from 1 – 500 seconds.
GZRAMP
Temperature Setpoint
Atmosphere Setpoint
Time
This is a guaranteed ramp opcode for a zone. The process value must be within the deviation band to allow
the ramp timer to run. If the temperature process value goes out of the deviation band, then the ramp
timer will stop and wait until the temperature process value comes back into the deviation band before
starting up again.
The Temperature Setpoint is the setpoint to send for the temperature process variable. The range is -301
(disable) to 30000.
The Time is the total time for the program to reach the desired setpoint(s), in Hours:Minutes format. The
Hours range from 0 – 166, and the Minutes range from 0 – 59.
The band limit can be changed by the
SET_WAIT
opcode.
HIGH_AL
Temperature Setpoint
Atmosphere Setpoint
N/A
This opcode is used to enable a high limit alarm on the temperature or atmosphere process. This alarm
remains active until the program ends.
The Temperature Setpoint is the setpoint to send for the temperature process variable. The range is -301
(disable) to 30000.
The Atmosphere Setpoint is the setpoint to send for the atmosphere process variable. The range is -0.01
(disable) to 99.99.
HIGH_PO
Temperature PO Value
Atmosphere PO Value
N/A