Super Systems AC20 User Manual
Page 88

86
INPUTS
INPUTS
INPUTS
INPUTS
INPUTS
A)
A)
A)
A)
A) MAIN INPUT
MAIN INPUT
MAIN INPUT
MAIN INPUT
MAIN INPUT
T y p e :
T y p e :
T y p e :
T y p e :
T y p e :
- 0 to 1500 mV (when mV sensor output or oxygen are selected
as primary controlled variable).
- 1000 to 1300 mV (when carbon potential or dew point is
selected as primary controlled variable).
NOTE:
NOTE:
NOTE:
NOTE:
NOTE: if the probe input value is out of the 1000 to 1300 mV,
the range automatically becomes 0 to 1500 mV.
Input type
Input type
Input type
Input type
Input type: isolated from others measuring inputs and digital
inputs.
Carbon range:
Carbon range:
Carbon range:
Carbon range:
Carbon range: 0.00 to 2.00%
Dew point range:
Dew point range:
Dew point range:
Dew point range:
Dew point range: -100 to 100 °F or -75 to 40 °C
Oxygen range:
Oxygen range:
Oxygen range:
Oxygen range:
Oxygen range:
0.0 to 25.0 %
R e s o l u t i o n :
R e s o l u t i o n :
R e s o l u t i o n :
R e s o l u t i o n :
R e s o l u t i o n :
0.1
mV range:
mV range:
mV range:
mV range:
mV range: 0 to 1500 mV
Cargon resolution:
Cargon resolution:
Cargon resolution:
Cargon resolution:
Cargon resolution: 0.01%
Dew point resolution
Dew point resolution
Dew point resolution
Dew point resolution
Dew point resolution: 1°F (1°C)
mV resolution
mV resolution
mV resolution
mV resolution
mV resolution: 1 mV
A c c u r a c y :
A c c u r a c y :
A c c u r a c y :
A c c u r a c y :
A c c u r a c y :
+ 0.02 digits for 0.40 to 1.60 % of the carbon range.
+ 0.03 digits for the remaining carbon range.
Temperature drift:
Temperature drift:
Temperature drift:
Temperature drift:
Temperature drift:
- 350 ppm/°C when the range is 1000 to 1300 mV.
- 200 ppm/°C when the range is 0 to 1500 mV.
Input impedance
Input impedance
Input impedance
Input impedance
Input impedance: > 100 M
Ω
Sampling time:
Sampling time:
Sampling time:
Sampling time:
Sampling time: 125 ms (typical).
Display updating time
Display updating time
Display updating time
Display updating time
Display updating time: 375 ms.
Insulation voltage:
Insulation voltage:
Insulation voltage:
Insulation voltage:
Insulation voltage: 500 VAC
Probe resistance:
Probe resistance:
Probe resistance:
Probe resistance:
Probe resistance: up to 100 K
Ω
Accuracy on probe resistance measurement:
Accuracy on probe resistance measurement:
Accuracy on probe resistance measurement:
Accuracy on probe resistance measurement:
Accuracy on probe resistance measurement: 2% f.s.v.
B) TEMPERATURE INPUT
B) TEMPERATURE INPUT
B) TEMPERATURE INPUT
B) TEMPERATURE INPUT
B) TEMPERATURE INPUT
Thermocouple type:
Thermocouple type:
Thermocouple type:
Thermocouple type:
Thermocouple type: K, S, R, B
Input type
Input type
Input type
Input type
Input type: not isolated from others measuring inputs and
digital inputs.
Sampling time:
Sampling time:
Sampling time:
Sampling time:
Sampling time: 1125 ms if carbon monoxide/remote set point
input is used.
750 ms otherwise.
Accuracy
Accuracy
Accuracy
Accuracy
Accuracy: + 0.2% f.s.v. + 1 digit @ 25 °C and nominal power
supply voltage.
Temperature drift:
Temperature drift:
Temperature drift:
Temperature drift:
Temperature drift: < 200 ppm/°C of full span
Source impedance:
Source impedance:
Source impedance:
Source impedance:
Source impedance: 100
Ω
max.
Current for TC open detection:
Current for TC open detection:
Current for TC open detection:
Current for TC open detection:
Current for TC open detection: -100 nA.
Cold junction
Cold junction
Cold junction
Cold junction
Cold junction: automatic compensation from 0 to 50 °C.
Cold junction accuracy
Cold junction accuracy
Cold junction accuracy
Cold junction accuracy
Cold junction accuracy : 0.1 °C/°C