beautypg.com

Super Systems AC20 User Manual

Page 87

background image

85

Common mode rejection

Common mode rejection

Common mode rejection

Common mode rejection

Common mode rejection: 120 dB @ 50/60 Hz.
Normal mode rejection

Normal mode rejection

Normal mode rejection

Normal mode rejection

Normal mode rejection: 60 dB @ 50/60 Hz.
Electromagnetic compatibility and safety require-

Electromagnetic compatibility and safety require-

Electromagnetic compatibility and safety require-

Electromagnetic compatibility and safety require-

Electromagnetic compatibility and safety require-
ments

ments

ments

ments

ments: This instrument is marked CE.
Therefore, it is conforming to council directives 89/336/EEC and
to council directives 73/23/EEC and 93/68/EEC.
Installation category

Installation category

Installation category

Installation category

Installation category: II
Operative temperature

Operative temperature

Operative temperature

Operative temperature

Operative temperature: from 0 to 50 °C (+32 to 122 °F).
Storage temperature

Storage temperature

Storage temperature

Storage temperature

Storage temperature: -20 to +70 °C (-4 to 158 °F)
Humidity

Humidity

Humidity

Humidity

Humidity: from 20 % to 85% RH, non condensing.
Altitude

Altitude

Altitude

Altitude

Altitude: This product is not suitable for use above 2000m
(6562ft).

GENERAL INFORMATION

GENERAL INFORMATION

GENERAL INFORMATION

GENERAL INFORMATION

GENERAL INFORMATION

GENERAL SPECIFICATIONS

GENERAL SPECIFICATIONS

GENERAL SPECIFICATIONS

GENERAL SPECIFICATIONS

GENERAL SPECIFICATIONS
Case

Case

Case

Case

Case: Polycarbonate black color; self-extinguishing degree: V-0
according to UL 94.
Front protection

Front protection

Front protection

Front protection

Front protection: designed for IP 65 (*) and NEMA 4X (*) for
indoor locations (when panel gasket is installed).
(*) Test were performed in accordance with IEC 529, CEI 70-1
and NEMA 250-1991 STD.
Installation

Installation

Installation

Installation

Installation: panel mounting.
Rear terminal block

Rear terminal block

Rear terminal block

Rear terminal block

Rear terminal block: 54 screw terminals (screw M3, for
cables from

φ

0.25 to

φ

2.5 mm

2

or from AWG 22 to AWG 14)

with connections diagram and safety rear cover.
Dimensions

Dimensions

Dimensions

Dimensions

Dimensions: according to DIN 43700
3.78" x 3.78" (96 x 96 mm), depth 5" (128 mm).
Weight

Weight

Weight

Weight

Weight:750 g (full option).
Power supply

Power supply

Power supply

Power supply

Power supply:
- 100 V to 240 V AC 50/60 Hz (-15% to + 10% of the nominal

value).

- 24 V AC/DC (+ 10 % of the nominal value).
Power consumption

Power consumption

Power consumption

Power consumption

Power consumption:
- 16 VA max. (without optional I/O)
- 20 VA max. (with optional I/O)
Insulation resistance

Insulation resistance

Insulation resistance

Insulation resistance

Insulation resistance: > 100 M

according to IEC 1010-1.

Dielectric strength

Dielectric strength

Dielectric strength

Dielectric strength

Dielectric strength: 1500 V rms according to IEC 1010-1.