81
R.M02 -
R.M02 -
R.M02 -
R.M02 -
R.M02 -
Maximum value of proportional band
Maximum value of proportional band
Maximum value of proportional band
Maximum value of proportional band
Maximum value of proportional band
calculated by SMART algorithm
calculated by SMART algorithm
calculated by SMART algorithm
calculated by SMART algorithm
calculated by SMART algorithm
This parameter is available only when smart function is
configured (“Sñ.Fn” [C.G01] = “Enb”)
Upper display: Gr.Hd
Lower display: Pb.Hi
Range: from “Pb.Lo” [R.M01] to 999.0%
NOTE
NOTE
NOTE
NOTE
NOTE: The resolution on “Pb.Hi” value is: 0.1% up to 10.0%;
1% up to 999.0
R.M03 -
R.M03 -
R.M03 -
R.M03 -
R.M03 -
Minimum value of integral time
Minimum value of integral time
Minimum value of integral time
Minimum value of integral time
Minimum value of integral time
calculated by SMART algorithm
calculated by SMART algorithm
calculated by SMART algorithm
calculated by SMART algorithm
calculated by SMART algorithm
This parameter is available only when smart function is
configured (“Sñ.Fn” [C.G01] = “Enb”)
Upper display: Gr.Hd
Lower display: ti.Lo
Range: from 00.01 mm.ss to “ti.Hi” [R.M04].
R.M04 -
R.M04 -
R.M04 -
R.M04 -
R.M04 -
Maximum value of integral time
Maximum value of integral time
Maximum value of integral time
Maximum value of integral time
Maximum value of integral time
calculated by SMART algorithm.
calculated by SMART algorithm.
calculated by SMART algorithm.
calculated by SMART algorithm.
calculated by SMART algorithm.
This parameter is available only when smart function is
configured (“Sñ.Fn” [C.G01] = “Enb”)
Upper display: Gr.Hd
Lower display: ti.Hi
Range: from “ti.Lo” [R.M03] to 20.00 mm.ss
R.M05 -
R.M05 -
R.M05 -
R.M05 -
R.M05 -
Relative gain of the secondary output
Relative gain of the secondary output
Relative gain of the secondary output
Relative gain of the secondary output
Relative gain of the secondary output
calculated by SMART algorithm.
calculated by SMART algorithm.
calculated by SMART algorithm.
calculated by SMART algorithm.
calculated by SMART algorithm.
This parameter is available only when smart function is
configured (“Sñ.Fn” [C.G01] = “Enb”) and a secondary control
output is configured.
Upper display: Gr.Hd
Lower display: rG.CL
Range: OFF = Smart algorithm does not calculate “r.Gn”
[R.D06] value.
On
= Smart algorithm calculates “r.Gn” [R.D06] value.
R.M06 -
R.M06 -
R.M06 -
R.M06 -
R.M06 -
Hidden group default data loading
Hidden group default data loading
Hidden group default data loading
Hidden group default data loading
Hidden group default data loading
Upper display: Gr.Hd
Lower display: dFLt.
Range: OFF = No loading data
On = loading data