Measurement Computing LogBook Series User Manual
Page 187

LogBook User’s Manual, Appendix A
887997
Supplement / HopNet Modems A-3
Configure the “Serial Port Fixed Baud Rate Setup” for Device: LogBook Serial Fixed
1. From the LogBook Configuration Applet, click
2. Set the Properties, via the LogBook Properties Tab, as follows:
Device Name: LogBook Serial Fixed
Connection Type: Serial Port (Fixed Baud)
Device Connection: COM1
Protocol: RS232
3. Set the Properties via the Port Settings Tab, as follows:
Bits per second: 19200
Flow control: Hardware
4. Click the
5. Click the
Configure the “Serial Port Fixed Baud Rate Setup” for Device: LogBook HopNet
1. From the LogBook Configuration Applet, click
2. Set the Properties, via the LogBook Properties Tab, as follows:
Device Name: LogBook HopNet
Connection Type: Serial Port (Fixed Baud)
Device Connection: COM1
Protocol: RS232
3. Set the Properties via the Port Settings Tab, as follows:
Bits per second: 115200 (see Note 1)
Flow control: Hardware
4. Click the
5. Click the
Note 1: The bits per second, in step 3 above for device “LogBook HopNet” does not need to match the
bits per second set for device “LogBook Serial Fixed.”