beautypg.com

Command code 1: program ppu, Command code 2: program two-wire/standalone, Command code 3: program allocation – Gasboy Atlas Fuel Systems Owner Manual User Manual

Page 37

background image

MDE-4363F Atlas™ Fuel Systems Owner’s Manual · September 2011

Page 33

Programming 8800 Models

The Atlas Fuel System

Manager Keypad Key Definitions and Use

Pin Code Entry

• Press Fl.
• Enter 4-digit ID (default is 2222) and press ENTER.
• Press F1 to exit any command code.
• Press F2 to return to normal operation.
• From Level 1 after entering pin code, you may enter any command code directly.

Command Code 1: Program PPU

• Press 1 and then press ENTER.
• Select Side (1 or 2) and then press ENTER.
• Select Grade and then press ENTER.
• Select Price Level and then press ENTER.
• Enter new PPU and then press ENTER.

(Repeat for other Side, Grade, and Price Level)

Command Code 2: Program Two-Wire/Standalone

• Press 2 and then press ENTER.
• Press Configuration number and then press ENTER where

0 = Standalone mode
1 = Two-wire mode (default)
2 = Pulse Output mode

Command Code 3: Program Allocation

• Press 3 and then press ENTER.
• Select Side (1 or 2) and then press ENTER.
• Select Hose/Grade and then press ENTER.
• Select Allocation amount and then press ENTER.

(Repeat for other Side, Hose, and Grade)

Key(s)

Definition/Use

0-9

Numeric Values

F1

Function 1 – Used to start dispenser programming and sequence among programming
and function codes. In general, each depression of F1 key will take user back to a
previous programming function selection. Depressing F1 from the normal dispenser
state will always initiate programming mode.
Note: Displays are always activated during programming mode.

F2

Function 2 – Used to exit programming mode and return to normal mode.

$Totals

Money Totals – Used to display money totals by side and grade. This key does not
require a security code. CLEAR key is used to exit money totals mode.

Vol. Total

Volume Totals – Used to display volume totals by side and grade. This key does not
require a security code. CLEAR key is used to exit volume totals mode.

ENTER

Value entry keys – sends the entered value to pump.

CLEAR

Clear key – Used to clear last keypad entry, and exit money and volume total mode.