MDE-4363F Atlas™ Fuel Systems Owner’s Manual · September 2011
Page 33
Programming 8800 Models
The Atlas Fuel System
Manager Keypad Key Definitions and Use
Pin Code Entry
• Press Fl.
• Enter 4-digit ID (default is 2222) and press ENTER.
• Press F1 to exit any command code.
• Press F2 to return to normal operation.
• From Level 1 after entering pin code, you may enter any command code directly.
Command Code 1: Program PPU
• Press 1 and then press ENTER.
• Select Side (1 or 2) and then press ENTER.
• Select Grade and then press ENTER.
• Select Price Level and then press ENTER.
• Enter new PPU and then press ENTER.
(Repeat for other Side, Grade, and Price Level)
Command Code 2: Program Two-Wire/Standalone
• Press 2 and then press ENTER.
• Press Configuration number and then press ENTER where
0 = Standalone mode
1 = Two-wire mode (default)
2 = Pulse Output mode
Command Code 3: Program Allocation
• Press 3 and then press ENTER.
• Select Side (1 or 2) and then press ENTER.
• Select Hose/Grade and then press ENTER.
• Select Allocation amount and then press ENTER.
(Repeat for other Side, Hose, and Grade)
Key(s)
Definition/Use
0-9
Numeric Values
F1
Function 1 – Used to start dispenser programming and sequence among programming
and function codes. In general, each depression of F1 key will take user back to a
previous programming function selection. Depressing F1 from the normal dispenser
state will always initiate programming mode.
Note: Displays are always activated during programming mode.
F2
Function 2 – Used to exit programming mode and return to normal mode.
$Totals
Money Totals – Used to display money totals by side and grade. This key does not
require a security code. CLEAR key is used to exit money totals mode.
Vol. Total
Volume Totals – Used to display volume totals by side and grade. This key does not
require a security code. CLEAR key is used to exit volume totals mode.
ENTER
Value entry keys – sends the entered value to pump.
CLEAR
Clear key – Used to clear last keypad entry, and exit money and volume total mode.